2OM-1075-002.pdf - 第289页

AHB01ESPP *6 "Control Sw" Group Box When the [ENABLE] button on the operation panel is pressed in two seconds after one of the buttons in the "Operation" group box (*1) is selected and the [ON] button…

100%1 / 469
AHB01ESPP
[B.P.C. Standby Posn] Button
Select a parameter as the standby position of the transferred
P.C.B. to be specified in the current pattern program.
Every time this button is pressed, the value in the text box
changes in scrolling such as "0" Æ "1" Æ "2" Æ "0".
"1" : Set this in the text box when a P.C.B. has no previously-
placed components and is positioned based on "Outline
Reference".
The P.C.B. backup base ascends to an area near the
P.C.B. transfer plane in advance and is set in the standby
mode during P.C.B. transfer operation.
"2" : Set this in the text box when the height of a previously-
placed component is less than 6.5 mm.
The P.C.B. backup base ascends to an area near "P.C.B.
Transfer Plane + Previously-Placed Component" in ad-
vance and is set in the standby mode during P.C.B. trans-
fer operation.
"0" : Set this in the text box when the height of a previously-
placed component is 6.5 mm or more.
The P.C.B. backup base is set in the standby mode at its
origin.
(a) The standby position is specified in the current pattern
program.
Set "0" (zero) when no pattern program is specified as
the current one.
(b) The parameters set here become valid only when a
transfer test is performed, using this tab sheet.
The standby position during automatic operation is de-
termined according to the operation data in the pattern
program.
*4 Cur (Current Values)
Displayed is the current value of each item to be adjusted.
The value specified in the current pattern program is set as a de-
fault value.
*5 Adj (Adjusted Values)
When the [PCB Thickness] button in the "B.P.C. Adj" group box (*3)
is pressed, the "PCB Thickness" edit window opens. Enter a nu-
merical value in the data input field and press the [Set] button. As for
the [B.P.C. Standby Posn] button, every time the button is pressed,
a parameter scrolls in the corresponding text box, enabling the op-
erator to select the desired parameter.
The entered value appears in each "Adj" text box.
Note
0308-003 6-56
4.1 "Conveyor Adj" Tab
AHB01ESPP
*6 "Control Sw" Group Box
When the [ENABLE] button on the operation panel is pressed in two
seconds after one of the buttons in the "Operation" group box (*1) is
selected and the [ON] button (entitled "MOVE") is pressed, the ac-
tion corresponding to the selected button takes place.
Operation Procedure
(1) Set parameters in the "Xfr Prmtr Adj" tab sheet.
(2) Select one of the buttons in the "Operation" group box (*1).
(3) Press the [ON] button (entitled "MOVE"). In 2 seconds, press the
[ENABLE] button on the operation panel.
0308-002 6-57
4.1 "Conveyor Adj" Tab
AHB01ESPP
4.1.2 "PCB Lct Sol Adj" Tab
The corresponding tab sheet enables the operator to activate the P.C.B.
locate solenoid.
Sheet Layout
When the "PCB Lct Sol Adj" tab is pressed in the "Conveyor Adj" tab
sheet, the following tab sheet appears.
Fig. 2F44 "PCB Lct Sol Adj" Tab Sheet
Sheet Composition
*1 "Operation" Group Box
The following buttons are provided in this group box.
Select the button to be operated.
[Stopper] Button
When pressed, this button activates P.C.B. Stopper P1 or P2.
[Width near] Button
When pressed, this button narrows the conveyor width, using
the P.C.B. YL or YR pusher.
[Clamp] Button
When pressed, this button activates the P.C.B. ZL or ZR clamp.
0308-004 6-58
4.1 "Conveyor Adj" Tab
*1
*2
*4
*3