2OM-1075-002.pdf - 第315页

AHB01ESPP • Sheet Layout When the "Pick-Up Location" tab is pressed in the "TEACHING" win- dow (submenu), the following tab sheet appears inside the window . Fig. 2F57 "Pick-Up Location" T a…

100%1 / 469
AHB01ESPP
5.1 "Pick-Up Location" Tab
The corresponding tab sheet enables the operator to correct the com-
ponent pick-up location.
The correction is made through the manual alignment operation.
Only a well-trained personnel shall perform teaching
operations.
The component library data and the pattern pro-
gram may be modified additionally for the teaching.
If the teaching operation is not performed correctly,
the pick-up rate may deteriorate.
This function can be used in the following cases.
Program Change
Feeder Replacement
Deteriorated Pick-Up Rate
(a) The objective feeders for teaching are those whose pick-
up position is registered in the placement feeder location
data of the current pattern program.
(b) The pick-up rate may be improved after the teaching of the
pick-up position is performed when the pick-up rate is low.
(c) When a component has a groove, a protrusion, etc., and
cannot be picked up at the center with any hindrance, it is
possible to perform the teaching operation on the desig-
nation of eccentric pick-up (the parameters to be specified
in the "X [mm]" and "Y [mm]" text boxes of the label "Pickup
pos correction" in the component library data). (*2 in Fig.
2F57)
(d) Menu selections become possible only when the machine
is in the "STOP" mode.
5.1 "Pick-Up Location" Tab
Note
0308-004 6-82
CAUTION
AHB01ESPP
Sheet Layout
When the "Pick-Up Location" tab is pressed in the "TEACHING" win-
dow (submenu), the following tab sheet appears inside the window.
Fig. 2F57 "Pick-Up Location" Tab Sheet
Sheet Composition
*1 [Tape, Vib. Stick Teach Pick-Up Pos. [Comp. Center Pos.]] But-
ton
When pressed, this button makes it possible to perform a teaching
operation to align the component center with the nozzle center.
When this button is pressed, the "Tape, Vib. Stick Teach Pick-Up
Pos. [Comp. Center Pos.]" sheet appears.
Refer to "5.1.1 "Tape, Vib. Stick Teach Pick-Up Pos. [Comp. Center
Pos.]" Sheet" for details.
*2 [Tape, Vib. Stick Teach Ecc. Pick-Up Pos. [Pickup Loc. Adj.]]
Button
When pressed, this button makes it possible to perform a teaching
operation on the eccentric pick-up correction position against hin-
drance to component picks at the center.
When this button is pressed, the "Tape, Vib. Stick Teach Ecc. Pick-
Up Pos. [Pickup Loc. Adj.]" sheet appears.
Refer to "5.1.2 "Tape, Vib. Stick Teach Ecc. Pick-Up Pos. [Pickup
Loc. Adj.]" Sheet" for details.
5.1 "Pick-Up Location" Tab
0206-003 6-83
*1
*2
*3
*4
AHB01ESPP
*3 [Vib. Stick Component Data Offset] Button
When pressed, this button makes it possible to perform a teaching
operation to align the center of the vacuum nozzle with the center of
the component supplied from the vibratory stick feeder.
When this button is pressed, the "Vib. Stick Component Data Off-
set" sheet appears.
Refer to "5.1.3 "Vib. Stick Component Data Offset" Sheet" for de-
tails.
*4 Other Buttons
These buttons are optional.
5.1 "Pick-Up Location" Tab
0206-003 6-84