2OM-1075-002.pdf - 第338页
AHB01ESPP • • • • • Pointing Device Operation "Center 1-Point Adjustment" A crosshair appears on the recognized image. Adjust the crosshair to the pick-up point, using the pointing device. (1) When the [ENABLE]…

AHB01ESPP
From the previous page
Select the [Manual Alignment] button and
press the [ON] button (entitled "MOVE").
After that, press the [ENABLE] button on the
operation panel in 2 seconds.
An expanded recognized image is dis-
played.
In the case of "Center 1-Pt.", the regis-
tration of the designated nozzle is made
together for graphic teaching to facilitate
the manual alignment operation with the
pointing device.
Positioning Operation with Pointing Device
Make the manual alignment accurately.
Refer to "Pointing Device Operation" (de-
scribed later) for details.
In the case of "Diagonal 2-Point Adjustment",
press the [2Point] button and follow the same
teaching procedure as the 1-point adjustment
(selection of the [1Point] button).
Selection of [End] Button
Selection of [YES] Button in "Confirmation"
Dialog Box for Replacement of Offset Data
Fig. 2F75-1
5.1 "Pick-Up Location" Tab
0206-003 6-105

AHB01ESPP
••
••
• Pointing Device Operation
"Center 1-Point Adjustment"
A crosshair appears on the recognized image.
Adjust the crosshair to the pick-up point, using the pointing device.
(1) When the [ENABLE] button on the operation panel is pressed in 2
seconds after the [Center 1-Pt.] button and the [ON] button (entitled
"MOVE"), the P.E.C. recognition camera moves to the designated
feeder No. position.
(2) Manipulate the pointing device as shown in figure below.
Fig. 2F76
"Diagonal 2-Point Adjustment"
Specify two edges of the component to be picked up.
Specify two edges of the component in the carrier stick.
Fig. 2F77
5.1 "Pick-Up Location" Tab
0206-003 6-106

AHB01ESPP
(1) When the [ENABLE] button on the operation panel is pressed in two
seconds after the [1Point] button and the [ON] button (entitled
"MOVE"), the P.E.C. recognition camera moves to the specified
feeder No. position.
A crosshair (first point) appears on the recognized image.
(2) Make an alignment with the pointing device and press the right and
left buttons simultaneously.
Fig. 2F78
(3) When the [ENABLE] button on the operation panel is pressed in 2
seconds after the [2Point] button and the [ON] button (entitled
"MOVE"), the P.E.C. recognition camera moves to the specified
feeder No. position.
A crosshair (second point) appears on the recognized image.
When the [ON] button (entitled "MOVE") is hidden behind
the recognized image, touch the image softly to make it
disappear and press the [ON] button.
(4) Make an alignment with the pointing device and press the right and
left buttons simultaneously.
Fig. 2F79
5.1 "Pick-Up Location" Tab
Note
0206-003 6-107