AHB01ESPP *2 Mode Selection Buttons V arious actions can be selected. The following button is provided in this group box. [All Beam (Incl. NC Axis) Heads Zero] Button When this button is pressed, all X/Y beams are zeroed…

100%1 / 469
AHB01ESPP
Sheet Composition
*1 "Select Option" Group Box
Select the head to be used for teaching operations.
The following buttons are provided in this group box.
[All Heads] Button
The machine performs the teaching operations on the offsets
of the P.E.C. recognition cameras on both X1 and X2 heads
and the beam offsets.
(a) The teaching operations are performed first on the X1
head and then the X2 head.
(b) Before performing any teaching operation, position the
jig P.C.B. and zero all beams.
[X1 Head] and [X2 Head] Buttons
When these buttons are pressed, the machine performs the
teaching operations on the offsets of the P.E.C. recognition
camera on the X1 or the X2 head and the beam offsets.
(a) The machine can perform the teaching operations re-
lated to only the X1 or the X2 head.
(b) Before performing any teaching operation, position the
jig P.C.B. and zero all beams.
[Camera-P1], [Beam Offset], [Camera-P2], and [Beam Offset]
Buttons
The machine performs an offset teaching operation for each
individual devices.
(a) Before performing any teaching operation, position the
jig P.C.B. and zero all beams.
(b) When a teaching operation must be implemented sepa-
rately, perform the teaching operation first on the cam-
era offsets and then the beam offsets. (To calculate
the beam offsets by using the results of the teaching
operation on the camera offsets)
Note
Note
Note
0206-003 6-146
5.3 "P.E.C. Recog Camr & Beam Ofs" Tab
AHB01ESPP
*2 Mode Selection Buttons
Various actions can be selected.
The following button is provided in this group box.
[All Beam (Incl. NC Axis) Heads Zero] Button
When this button is pressed, all X/Y beams are zeroed.
[Teach Start] Button
When this button is pressed, a teaching operation is performed on
the selected item.
[Chute Mark Recog.] Button
When this button is pressed, the fiducial mark on the chute is rec-
ognized to determine whether or not a teaching operation must be
performed.
When there is a big difference between the current and adjusted
values (results of chute mark recognition) in the display area of the
offset values (*4), it means that a teaching operation is required.
*3 Set Status
When the "P.E.C. Dsbl." or the "Comp. Recognition Dsbl." check
box in the "Test Run" window is turned on (checked), the background
color of "Recognition Dsbl." turns light red. (No background color in
normal cases)
No recognition processing is made even if a teaching op-
eration is performed when each check box is turned on
(checked) in the "Test Run" window. Therefore, various
teaching operations will get incorrect results.
When "All Beam (Incl. NC Axis) Heads Zero" is completed, the back-
ground color of "All Beam Zero" turns green. (Otherwise, the back-
ground has no color.)
(a) When each device is not zeroed and the teaching op-
erations are performed, note that the offset values may
not be taught correctly.
(b) Before performing a teaching operation, be sure to zero
all beams.
*4 Offset Values
Displayed are the current values and the adjusted ones after teach-
ing.
Note
Note
0206-003 6-147
5.3 "P.E.C. Recog Camr & Beam Ofs" Tab
AHB01ESPP
*5 Y2 Offset Difference
Shown are the values to be added to the Y-axis origin offset (Y2) for
tilting correction of the beam X axis.
After the teaching operation, the values must be used in the follow-
ing formula.
(X1+X2)/2
Enter the result in the "Y2 [mm]" text box in the "Y-Axis" tab sheet
that belongs to the "Offset Data" tab sheet in the "Machine System
Data - [Internal Editor]" window.
*6 [P.C.B. Transfer Manual Mode] Button
When this button is pressed, the "P.C.B. Transfer Manual Mode"
sheet appears.
Refer to "5.3.1 "P.C.B. Transfer Manual Mode" Sheet" for details.
*7 [Jig P.C.B.] Button
When this button is pressed, the "Jig P.C.B." sheet appears.
Refer to "5.3.2 "Jig P.C.B." Sheet" for details.
*8 [Clear Adj.] Button
When pressed, this button clears the results of the teaching opera-
tion.
*9 [Cancel] Button
When pressed, this button ends the teaching operation without re-
flecting the teaching results on the offset data.
*10 [End] Button
When this button is pressed, a "Confirmation" dialog box opens.
Fig. 2F106
When the [YES] button is pressed, the results of the teaching op-
eration is reflected on the offset data, and exits from this session.
*11 "Control Switch" Group Box
Select the items (buttons) to be taught and press the [ON] button
entitled "MOVE". After that, press the [ENABLE] button on the op-
eration panel in 2 seconds. A teaching operation is performed on
the selected item.
0206-003 6-148
5.3 "P.E.C. Recog Camr & Beam Ofs" Tab