2OM-1075-002.pdf - 第402页
AHB01ESPP *5 Offset V alues Displayed are the current values and the adjusted ones after teach- ing. *6 [Manual Nozzle Change] Button When this button is pressed, the "Nozzle Change" window appears. Refer to &q…

AHB01ESPP
[X1 Head] and [X2 Head] Buttons
When pressed, the button performs the teaching operation on
the corresponding head (X1 or X2).
Before performing the teaching operation, zero all beams.
*2 [Fdr. No.] Button
When this button is pressed, the "Fdr. No." edit window opens. En-
ter the feeder No. to which the head must be moved, using the ten-
key pad.
*3 "Selection of Teaching Operation" Group Box
The following buttons are provided in this group box.
[All Beam Heads Zero] Button
When this button is pressed, all X/Y beams are zeroed.
[Teach Start] Button
When this button is pressed, a teaching operation is performed
on the selected nozzle.
[Movement to Nozzle Placement Position] Button
When this button is pressed, the head moves to the specified
feeder No. (Fdr. No.) position.
*4 Set Status
When the "P.E.C. Dsbl." or the "Comp. Recognition Dsbl." check
box in the "Test Run" window is turned on (checked), the background
color of "Recognition Dsbl." turns light red. (No background color in
normal cases).
No recognition processing is made even if a teaching op-
eration is performed when each check box is turned on
(checked) in the "Test Run" window. Therefore, various
teaching operations will get incorrect results.
When "All Beam (Incl. NC Axis) Heads Zero" is completed, the back-
ground color of "All Beam Zero" turns green. (Otherwise, the back-
ground has no color.)
(a) When each device is not zeroed and the teaching op-
erations are performed, note that the offset values may
not be taught correctly.
(b) Before performing a teaching operation, be sure to zero
all beams.
Note
Note
0308-003 6-167
Note
5.9 "Head Center Ofs" Tab

AHB01ESPP
*5 Offset Values
Displayed are the current values and the adjusted ones after teach-
ing.
*6 [Manual Nozzle Change] Button
When this button is pressed, the "Nozzle Change" window appears.
Refer to "4.3 "Nozzle Change" Tab" for details.
*7 [Clear Adj.] Button
When pressed, this button clears the results of the teaching opera-
tion.
*8 [Cancel] Button
When pressed, this button ends the teaching operation without re-
flecting the teaching results on the offset data.
*9 [End] Button
When pressed, this button reflects the results of the teaching op-
eration on the offset data and exits from this session.
*10 "Control Switch" Group Box
Select the items (buttons) to be taught and press the [ON] button
entitled "MOVE". After that, press the [ENABLE] button on the op-
eration panel in 2 seconds. A teaching operation is performed on
the selected item.
0308-003 6-168
5.9 "Head Center Ofs" Tab

AHB01ESPP
• Preparation for Teaching Operations
Nozzles
Prepare either [EF01] or [EF02].
Teaching Plate
(Component Recognition Offset Jig: JG-0085)
(Standard Accessory Part)
Handle this fragile jig very carefully.
Fig. 2F115
2 types of patterns are printed through vapor deposition on the glass
for positional calculation.
• Teaching Procedure
(1) Attach the nozzle by hand.
(2) Attach the jig component (the teaching plate (component recogni-
tion offset jig)) to the position where the teaching plate is attached.
The printed side of the component recognition offset jig
should face downward.
(3) Confirm the following.
• The machine is powered.
• The safety doors are completely closed.
(3-1) Press the [Movement to Nozzle Placement Position] button
and bring the head over to the specified feeder No.
(3-2) Press the [Select Nozzle] button in the "Nozzle Change" sheet
to move Nozzle #1 to the "Noz #1" position.
Note
Note
0206-002 6-169