AHB01ESPP 5.19 "Nozzle Center Ofs" T ab The corresponding tab sheet enables the operator to perform the teach- ing operation on the nozzle center offset. • • • • • Sheet Layout When the "Nozzle Center Ofs&…

AHB01ESPP
*3 Set Status
When the "P.E.C. Dsbl." or the "Comp. Recognition Dsbl." check
box in the "Test Run" window is turned on (checked), the background
color of "Recognition Dsbl." turns light red. (No background color in
normal cases).
No recognition processing is made even if a teaching op-
eration is performed when the each check box is turned on
(checked) in the "Test Run" window. Therefore, various
teaching operations will get incorrect results.
When "All Beam (Incl. NC Axis) Heads Zero" is completed, the back-
ground color of "All Beam Zero" turns green. (Otherwise, the back-
ground has no color.)
(a) When each device is not zeroed and the teaching op-
erations are performed, note that the offset values may
not be taught correctly.
(b) Before performing a teaching operation, be sure to zero
all beams.
*4 Offset Values
Displayed are the current values and the adjusted ones after teach-
ing.
*5 [Clear Adj.] Button
When pressed, this button clears the results of the teaching opera-
tion.
*6 [Cancel] Button
When pressed, this button ends the teaching operation without re-
flecting the teaching results on the offset data.
*7 [End] Button
When pressed, this button reflects the results of the teaching op-
eration on the offset data and exits from this session.
*8 "Control Switch" Group Box
Select the items (buttons) to be taught and press the [ON] button
entitled "MOVE". After that, press the [ENABLE] button on the op-
eration panel in 2 seconds. A teaching operation is performed on
the selected item.
Note
Note
0206-002 6-197
5.18 "Teaching Plate Ofs" Tab

AHB01ESPP
5.19 "Nozzle Center Ofs" Tab
The corresponding tab sheet enables the operator to perform the teach-
ing operation on the nozzle center offset.
••
••
• Sheet Layout
When the "Nozzle Center Ofs" tab is pressed in the "TEACHING" win-
dow (submenu), the following tab sheet appears inside the window.
Fig. 2F128 "Nozzle Center Ofs" Tab Sheet
••
••
• Sheet Composition
*1 "Select Head" Group Box
The following buttons are provided in this group box.
[X1 Head] and [X2 Head] Buttons
*2 "Select Nozzle" Group Box
Select the nozzle position to be taught.
*3 [Fdr. No.] Button and Text Box
When this button is pressed, the "Fdr. No." edit window opens. En-
ter the feeder No. to which the head must be moved, using the ten-
key pad.
*4 "Selection of Teaching Operation" Group Box
The following buttons are provided in this group box.
[All Beam Heads Zero] Button
When this button is pressed, all X/Y beams are zeroed.
0206-002 6-198
5.19 "Nozzle Center Ofs" Tab
*12
*11
*9
*5
*1
*2
*3
*4
*6
*7
*8
*10

AHB01ESPP
[Teach Start] Button
When this button is pressed, the machine performs a teaching op-
eration on the selected item.
[Movement to Nozzle Attachment Position] Button
When this button is pressed, the head moves to the specified feeder
No. (Fdr. No.) position.
*5 Offset Values
Displayed are the current values and the adjusted ones after teach-
ing.
*6 Set Status
When the "P.E.C. Dsbl." or the "Comp. Recognition Dsbl." check
box in the "Test Run" tab sheet is turned on (checked), the back-
ground color of "Recognition Dsbl." turns light red. (No background
color in normal cases).
No recognition processing is made even if a teaching op-
eration is performed when the each check box is turned on
(checked) in the "Test Run" window. Therefore, various
teaching operations will get incorrect results.
When "All Beam (Incl. NC Axis) Heads Zero" is completed, the back-
ground color of "All Beam Zero" turns green. (Otherwise, the back-
ground has no color.)
(a) When each device is not zeroed and the teaching op-
erations are performed, note that the offset values may
not be taught correctly.
(b) Before performing a teaching operation, be sure to zero
all beams.
*7 [Manual Nozzle Change] Button
When this button is pressed, the "Nozzle Change" sheet appears.
Refer to "4.3 "Nozzle Change" Tab" for details.
*8 [Nozzle Attachment/Storage] Button
When this button is pressed, the "Nozzle Attachment/Storage Test"
sheet appears.
Refer to "5.19.1 "Nozzle Attachment/Storage Test" Sheet" for de-
tails.
*9 [Clear Adj.] Button
When pressed, this button clears the results of the teaching opera-
tion.
*10 [Cancel] Button
When pressed, this button ends the teaching operation without re-
flecting the teaching results on the offset data.
5.19 "Nozzle Center Ofs" Tab
Note
Note