AHB01ESPP *8 [Clear Adj.] Button When pressed, this button clears the results of the teaching opera- tion. *9 [Cancel] Button When pressed, this button ends the teaching operation without re- flecting the teaching result…

100%1 / 469
AHB01ESPP
*3 [Fdr. No.] Button and Text Box
When this button is pressed, the "Fdr. No." edit window opens. En-
ter the feeder No. to which the head must be moved, using the ten-
key pad.
*4 "Select Mode (Items to be taught)" Group Box
The following buttons are provided in this group box.
[All Beam Heads Zero] Button
When this button is pressed, all X/Y beams are zeroed.
[Teach Start] Button
When this button is pressed, the machine performs a teaching op-
eration on the selected item.
[Movement to Nozzle Attachment Position] Button
When this button is pressed, the head moves to the specified feeder
No. (Fdr. No.) position.
*5 Offset Values
Displayed are the current values and the adjusted ones after teach-
ing.
*6 Set Status
When the "P.E.C. Dsbl." or the "Comp. Recognition Dsbl." check
box in the "Test Run" tab sheet is turned on (checked), the back-
ground color of "Recognition Dsbl." turns light red. (No background
color in normal cases)
No recognition processing is made even if a teaching op-
eration is performed when the each check box is turned on
(checked) in the "Test Run" tab sheet. Therefore, various
teaching operations will get incorrect results.
When "All Beam (Incl. NC Axis) Heads Zero" is completed, the back-
ground color of "All Beam Zero" turns green. (Otherwise, the back-
ground has no color.)
(a) When each device is not zeroed and the teaching op-
erations are performed, note that the offset values may
not be taught correctly.
(b) Before performing a teaching operation, be sure to zero
all beams.
*7 [Manual Nozzle Change] Button
When this button is pressed, the "Nozzle Change" sheet appears.
Refer to "4.3 "Nozzle Change" Tab" for details.
5.20 "Nozzle Tip Pos Ofs" Tab
Note
Note
0308-004 6-203
AHB01ESPP
*8 [Clear Adj.] Button
When pressed, this button clears the results of the teaching opera-
tion.
*9 [Cancel] Button
When pressed, this button ends the teaching operation without re-
flecting the teaching results on the offset data.
*10 [End] Button
When pressed, this button reflects the results of the teaching op-
eration on the offset data and exits from this session.
*11 "Control Switch" Group Box
Select the items (buttons) to be taught and press the [ON] button
entitled "MOVE". After that, press the [ENABLE] button on the op-
eration panel in 2 seconds. A teaching operation is performed on
the selected item.
5.20 "Nozzle Tip Pos Ofs" Tab
0206-003 6-204
AHB01ESPP
5.21 "Head Master Offset" Tab
The corresponding tab sheet enables the operator to perform a teach-
ing operation on the head master offsets.
This teaching operation must be performed only by our service
personnel.
Sheet Layout
When the "Head Master Offset" tab is pressed in the "TEACHING" win-
dow (submenu), the following tab sheet appears inside the window.
Fig. 2F132 "Head Master Offset" Tab Sheet
Sheet Composition
*1 "Select Head" Group Box
Select the head to be used for teaching operations.
The following buttons are provided in this group box.
[X1 Head] and [X2 Head] Buttons
*2 "Select Nozzle" Group Box
Select the nozzle position to be taught.
*3 Fdr. No.
When this button is pressed, the "Fdr. No." edit window opens. En-
ter the feeder No. to which the head must be moved, using the ten-
key pad.
5.21 "Head Master Offset" Tab
Note
*2
*1
*3
*4
*8
*9
*10
*11
*7
*6
*5