1.2.4 Component Placement P .C.B. Positioning Section: Component Placement • The heads move to the area over the placement coordinates on the P .C.B. specified in the pattern program. The deviation (X, Y) of the pick-up …

100%1 / 469
Component Storage Box: Component Discharge
When a recognition error occurs during the component recogni-
tion, the head moves to the component storage box and discharges
the error-caused component.
Fig. 2B15 Component Discharge
0206-003 2-10 AHB01ESPP
1.2 Component Placement (starting with preparation for component picks)
1.2.4 Component Placement
P.C.B. Positioning Section: Component Placement
The heads move to the area over the placement coordinates on the
P.C.B. specified in the pattern program.
The deviation (X, Y) of the pick-up position (measured through the
component recognition) is also corrected at this time.
Fig. 2B16 Movement to Area over Placement Coordinates
When a component is placed, the lowest limit of the required nozzle
is controlled according to the component library data.
The vacuum valve closes, air blows out from the nozzle, and the
component is placed on the P.C.B.
0206-002 2-11
AHB01ESPP
1.2 Component Placement (starting with preparation for component picks)
1.3 Discharge of P.C.B.
(1) The components-placed P.C.B. is carried out to the R conveyor.
At the same time, a new P.C.B. is carried to the P.C.B. positioning
section from the L conveyor.
Fig. 2B17
(2) The components-placed P.C.B. on the R conveyor is transferred to
the output machine by the R conveyor.
Fig. 2B18
0206-003 2-12
AHB01ESPP
1.3 Discharge of P.C.B.