00198045-01_OM_BulkFeeder_X_EN - 第15页

SIPLACE BulkFeede r X / Operating Ma nual 05/2017 Edition 15 3.4 Controls and Dis plays of the Base Unit The control panel is a 7 - segment displa y. The SIPLACE B ulkFeeder X has a main menu and submenus. After switch -…

100%1 / 48
SIPLACE BulkFeeder X / Operating Manual 05/2017 Edition
14
Figure 3-3: Fiducials for SIPLACE Vision
The plate shutter can be opened and closed via the corresponding buttons on the feeder or under
Manual Operations on the station software GUI.
DANGER
Do not open the plate shutter manually! This may cause malfunction of the shutter
mechanism.
The container shutter is a shaft with a groove that runs in a sliding sleeve. The function of the
container shutter is to block the glass plate from being filled by slipping components when the
Cartridge is removed. For this, the components are vibrated behind the shutter and the shutter gets
closed before the Cartridge is removed.
The container shutter can be opened and closed via the corresponding buttons on the feeder or
under Manual Operations on the station software GUI.
3.3 Feeding principle
A vibration and shutter mechanism pours loose components onto a glass pickup plate. An
integrated camera takes a picture of the components from underneath the glass plate. The station
computer analyzes the image, identifies the components that are suitable for pickup and
determines their position and alignment.
SIPLACE BulkFeeder X / Operating Manual 05/2017 Edition
15
3.4 Controls and Displays of the Base Unit
The control panel is a 7-segment display.
The SIPLACE BulkFeeder X has a main menu and submenus. After switch-on, the main menu is
automatically displayed.
1. 7-segment display
2. Forwards button
3. Backwards button
4. Remove cartridge button
5. Set button
6. Status display (green after login)
Figure 3-4: Control and display panel
Press the Set and Remove cartridge buttons shortly at the same time (< 2 seconds) to switch
over to the submenu.
Press the Set button > 2 seconds to switch over from a standard submenu to an advanced
submenu within the menu mode.
The decimal points in the display at the top indicate that the submenu mode is activated.
The submenu mode is automatically terminated if no button has been pressed within 15 seconds.
In this case, a possibly changed value will not be saved.
SIPLACE BulkFeeder X / Operating Manual 05/2017 Edition
16
Buttons
Buttons Action In submenu
Forwards
Vibrate forwards (batch 1) Increase parameter
Backwards
Vibrate backwards (batch 2) Decrease parameter
Open plate shutter
Close plate shutter
>0,75 sec.: unlock cartridge Save
>2 sec.: scan request Short: next menu
>2 sec.: advanced menus
Display submenu
Figure 3-5: Buttons on SIPLACE BulkFeeder X
Displays
Mode 7 segment display Status LED
Initial state Off Green
Internal feeder error FE or Er
01 01
Red
Station error Off Red
Plate shutter
confirmation
PS + OP (Plate shutter open)
PS + CL (Plate shutter closed)
(is displayed after the green button has been
pressed until the gray button is released)
Corresponds to feeder state
Automatically process
during
removing/inserting
cartridge is running
Corresponds to feeder state
Cartridge unlocked rS
Ou (Ou flashes)
Corresponds to feeder state
Cartridge not inserted
(The indicator flashes)
Corresponds to feeder state
Submenu x.x (x.x = name)
yy (yy = value)
Corresponds to feeder state
Figure 3-6: Displays on SIPLACE BulkFeeder X