EDM V2.2 / User Guide Ausgabe 10/2013 Edition
71
xmlImportVisionData
AdvancedAction
Integer
(9)
L;M;C;P;D
Sets the VisionDataAdvancedAction
property of XmlImport (6.2.6.29).
Fallback value, will be overwritten by
the value defined in the
MachineConfiguration.
configurationServerHost String
(localhost)
S; D
Name of the configuration server to
start the Web-Service on (reserved for
future use in a muti-network
environment). Currently always
"localhost".
The value is used only if the
ConfigurationMode (registry) is set to
"server".
configurationServerPort String
(9003)
S; D
Port to start the configuration server on
(Default value 9003).
The value is used only if the
ConfigurationMode (registry) is set to
"server".
ForceUserEntryInCommentDialog Boolean
(true)
L; D
This value indicates whether the user
name may be empty.
ForceCommentEntryInCommentDialog Boolean
(true)
L; D
This value indicates whether the
comment may be empty.
ForceCategoryEntryInCommentDialog Boolean
(true)
L; D
This value indicates whether the
comment category name may be
empty.
ClearCommentInCommentDialog Boolean
(true)
L; D
This value indicates whether the
previously entered comment is active
when opening a comment dialog.
ClearUserInCommentDialog Boolean
(true)
L; D
This value indicates whether the
previously entered user name is active
when opening a comment dialog.
ClearCategoryInCommentDialog Boolean
(true)
L; D
This value indicates whether the
previously selected comment
category is active when opening a
comment dialog.
SetUserInCommentDialogTo String
("")
L; D
The User value can be set to a fixed
value. There are two special values:
"[SiplaceProUserName]" and
"[WindowsUserName]" that will be
replaced if the SIPLACE or Windows
user name.
disableUserEntryInCommentDialog Boolean
(false)
L; D
Disable the input for the user name (if
user name entry is disabled the
ForceUserEntry… setting is ignored).
DisableEdmToolQuitMenu Boolean
(false)
T; D
Option to disable the "Quit"-Menu in the
EDM Tool.
LimitEdmToolExitToAdmins Boolean
(true)
T; D
Option to disable the "Quit"-Menu in the
EDM Tool for normal users.
AllowQuittingEdmToolWithActiveBlockingReasons Boolean
(false)
T; D
Option to enable Quitting the EDM Tool
while a Comment or Push Confirmation
Dialog is displayed.

EDM V2.2 / User Guide Ausgabe 10/2013 Edition
72
EdmConfigurationService.Binding.OpenTimeout Time
(PT1M)
All; D
The Open-Timeout of the EDM
Configuration Server Web-Service /
Client.
EdmConfigurationService.Binding.CloseTimeout Time
(PT1M)
All; D
The Close-Timeout of the EDM
Configuration Server Web-Service /
Client.
EdmConfigurationService.Binding.ReceiveTimeout Time
(PT10M)
All; D
The Receive-Timeout of the EDM
Configuration Server Web-Service /
Client.
EdmConfigurationClient.KeepAliveIntervall Time
(PT1M)
All; D
Interval a configuration client sends a
"KeepAlive" request to the configuration
server. Must be smaller as the receive
timeout.
EdmConfigurationService.Binding.MaxConnections Integer
(50)
All; D
Maximum number of connections to the
EDM Configuration server.
PreservePcbBarcodesDuringMasterImport Boolean
(true)
M;C;D
If set to "true", do not overwrite the
PCB barcodes in the master database
with the (local) barcodes from the Line
Server.
SkipOptimisationResultsForNotifications Boolean
(false)
M;C;D
If set to true the optimization results
(head steps…) will not be transferred to
the master server when changing a job
at the line.
UseSmtpAuthentification Boolean
(false)
F; M; D
Enable (experimental) authentication
with username and password when
sending E-Mail notifications.
CompressionHelper.ZipCompressionLevel Integer
[0..9]
(9)
All; D
Compression rate for the EDM data
transfer. Specifies the compression
level of the algorithm used; A lower
compression rate can be required if
memory problems arise as a result of
large volumes of data during
compression.
Value range: 0 through 9.
CompatibilityMode Boolean
(false)
L; M; D
If true: Allows restricted operation of an
EDM Line Server together with an EDM
< 2.1 Master Server. (See EDM
Installation Manual).
Caution: This mode must not be used
for long-term mixed operation, but only
for step-by-step upgrading the EDM
system from < 2.1. The Modified Object
protection is inactive when the
compatibility mode is active!
Note: This setting is not required when
upgrading from EDM 2.1 or higher.
Table 6-8: Settings in the SystemConfig.xml file
EDM V2.2 / User Guide Ausgabe 10/2013 Edition
73
6.2.6.1 Server Type
Ke
y:
serverType
Type:
Enum
Values:
NONE
LINE
MASTER
BOTH
CLEARINGPOOL
CONFIGSERVE
R
CONFIGMASTER
CONFIGLINE
ALL
Line + Master
Config Server + Master
Config Server + Line
Config Server + Master + Line + CP + …
Valid for:
All EDM Computers running an EDM Service
Description:
Specifies the type of installation. The EDM server is started as a Line Server,
Master Server or
hybrid depending on this setting.
NOTE: The hybrid settings "BOTH" and "ALL"
should only be used for test
pur
poses!
NOTE: This value is replaced with the valu
e from the MachineConfig.xml (see 0).
This is the fallback value for EDM Computers that have no entry in the Machine
Configuration. The default value is "NONE".
6.2.6.2 Help Folder
Key:
helpDirectory
Type:
Path
Default:
[AppDir]\help
Valid for:
Line server
Master server
Clearing pool
EDM Tool
Description:
Folder for online documentation
6.2.6.3 Distribution List For EDM Notifications
Key:
notificationDistributorClass
Type:
Class
Default:
Siemens.SiplacePro.EDM.DataExchange.EmailDistributor,
DataExchange
Valid for:
Master server
Description:
Class, i.e. implementation of the notification service. At present, distribution via
email is available using the default value as a
reference.
Note:
The notificationDistributor class interface has been changed with EDM 2.1.