00191017-01 - 第515页

User ’s Manual Line Computer UNIX 17.3 Description of Components and P CBs Software V e rsion 403.xx Ed ition 06/97 17.3.1 PCB 1: single circuit 17 - 1 7 To enter the dimensions of the PCB, proceed as f ollows: 22. Act i…

100%1 / 589
17.3 Description of Components and PCBs User’s Manual Line Computer UNIX
17.3.1 PCB 1: single circuit Software Version 403.xx Edition 06/97
17 - 16
Entering the dimens-
ions of the PCB
Defining fiducials
continued from page 17-14
PCB Description
Cluster Editor
Fiducial Editor
continued on page 17-18
User’s Manual Line Computer UNIX 17.3 Description of Components and PCBs
Software Version 403.xx Edition 06/97 17.3.1 PCB 1: single circuit
17 - 17
To enter the dimensions of the PCB, proceed as follows:
22. Activate the Select icon .
23. Click on the PCB (rectangle).
The rectangle is highlighted in green.
24. On the
SERVICES
menu click on the
Cluster Editor...
option.
The Cluster Editor is opened.
25. Enter the dimensions of the PCB. See
Fig. 17.3.1
on page 17-
12
and
Fig. 17.3.2
.
Fig. 17.3.2 Cluster Editor for PCB 1
To define the fiducials, proceed as follows:
26. In the Cluster Editor click on the
Edit fiducials
button.
The Fiducial Editor is opened.
27. Activate the
Insert
button.
28. Click on the
Fiducial set name
editing field.
29. Enter the name for the new fiducial set, here:
Set_1
.
30. Click on the
Accept fiducial set
button.
Fiducial set Set_1
appears on the fiducial list.
31. Click on fiducial set Set_1
on the fiducial list.
32. Click on the
Fiducial
editing field.
33. Enter the fiducial number, here:
48
.
34. Click on the editing fields for the coordinates, enter coordinates
(do not confirm by pressing the Enter key!), here: see chart:
35. Click on the
Accept fiducial data
button.
The fiducial data are transferred to the list of the fiducials of the fiducial set.
36. Define the other fiducials accordingly, here:
fiducials
48
and
48
.
37. Activate the
PCB position recognition
button.
38. Click on fiducial set Set_1 on the fiducial list.
The fiducial set
Set_1
is marked by a preceeding
L
for PCB position recognition.
Fiducial number X Y
48 -5 30
48 81 -10
48 81 30
Activate the PCB position
recognition
17.3 Description of Components and PCBs User’s Manual Line Computer UNIX
17.3.1 PCB 1: single circuit Software Version 403.xx Edition 06/97
17 - 18
No ink spot present.
No clusters and single circuits
present.
FILE
Save
FILE
Quit
Entering placement
positions
Defining ink spot
Saving PCB data
Creating clusters and
single circuits
continued from page 17-16
PCB Description
Placement Position Editor