To define the ink spot, proceed as follows:
140.In the Fiducial Editor activate the
Insert
button.
141.Click on the
Fiducial set name
editing field.
142.Enter a name for the new fiducial set (ink spot), here:
ink
.
143.Click on the
Accept fiducial set
button.
The ink fiducial set appears on the fiducial list.
144.Click on the ink fiducial set on the fiducial list.
145.Click on the
Fiducial
editing field.
146.Enter the fiducial number, here:
48
.
147.Click on the individual editing fields for the coordinetes and enter
the coordinates (do not confirm with the Enter key), here: see chart:
148.Click on the
Accept fiducial data
button.
The data of the ink spot are transferred to the list of the fiducials of the fiducial set.
149.Activate the
Ink spot fiducial set
button.
150.Click on the ink fiducial set on the fiducial list.
The ink fiducial set name is preceded by an
I
for ink spot.
151.Click on the
Quit
option on the
FILE
menu.
The Fiducial Editor is closed.
152.In the Cluster Editor click on the
Quit
option on the
FILE
menu.
The Cluster Editor is closed.
To create clusters and single circuits, proceed as follows:
no clusters and single circuits are present.
To enter the placement positions, proceed as follows:
153.In the Component Editor activate the Select icon .
154.Click on the PCB (rectangle).
The rectangle is highlighted in green.
155.Click on the
Placement Position Editor
option on the
SERVICES
menu.
The Placement Position Editor is opened.
156.Position the cursor in the entry field and enter the placement positions in accordance with
Section Tab.
17.3-3
on page 17-10. The individual entries are to be separated by a blank. Every line is to be confirmed
by
pressing the Enter key. See also
Fig. 17.3.6
on page 17-30.
157.When the entry has been completed, activate the Check icon .
The values entered are checked and arranged in columns.
158.Click on the
Quit
option on the
FILE
option.
The Placement Position Editor is closed.
To save the PCB data, proceed as follows:
159.In the PCB Editor click on the
Save
option on the
FILE
menu.
The PCB data are saved.
160.Click on the
Quit
option on the
FILE
menu.
The PCB Editor is closed. The description of PCB 2 is terminated.
Fiducial number X Y
48 15 0

17.3 Description of Components and PCBs User’s Manual Line Computer UNIX
17.3.2 PCB 2: Focus on Package Form Description Software Version 403.xx Edition 06/97
17 - 40
Fig. 17.3.6 Placement Position Editor for PCB 2
Enter fiducial set name
# = no fiducials defined for the
placement position
b = placing
k = glueing
d = dispensing (solder paste)
n = reworking
s = blocking (from placement)
Enter number of placement
level
# = no level defined for the pla-
cement position

User’s Manual Line Computer UNIX 17.3 Description of Components and PCBs
Software Version 403.xx Edition 06/97 17.3.3 PCB 3: Focus on Cluster Technique
17 - 41
pattern_2
pattern_1
pattern_3
pattern_4
board 1
board2
board 3
board 1
board2
board 3
board 3
board2
board 1
board 3
board2
board 1
Example_3
5
10
15
Corner
17.3.3 PCB 3: Focus on Cluster Technique
PCB 3 consists of four clusters (pattern) each of which comprises three single circuits (board). The dimensions
and the placement configuration of the single circuits corresponds to those of PCB 2. Clusters 3 and 4 are ro-
tated by 180°. For each cluster a PCB position recognition operation is performed. Three fiducials are available
in each case. An ink spot is located on each single circuit.
335
272
5
X
Y
PCB coordinate
system 0°
Direction of travel
150
116
10
15
60
105
165
Corner
PCB height= 1.5 mm
Zero point of the different levels:
PCB, cluster, single circuit
Ink spot
Fig. 17.3.7 Dimensions PCB 3
252
160
315