7OM-1603-006_w - 第147页
7OM-1603 4-16 Chapter 4 : 3. Maintenance Spots Linear Guide Every 3 Months Lubrication (DAPHNE EPONEX GREASE No. 1) Required T ime: 5 minutes W ipe off old grease with an oiled rag and apply new one with a brush or suppl…

7OM-1603
Chapter 4 : 3. Maintenance Spots
4-15
Elevator Clamp Rod
Every Year Inspection
Required Time : 1 minute
Check any sign of abrasion on the clamp
rod visually.
F7D7
0908-001

7OM-1603
4-16
Chapter 4 : 3. Maintenance Spots
Linear Guide
Every 3 Months Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
Wipe off old grease with an oiled rag and
apply new one with a brush or supply
grease from eight grease nipples with a
grease gun.
Take ample care not to leave any
waste threads after cleaning.
Belt
Every Year Inspection
Required Time: 1 minute
Visually inspect the wear of the belt.
Notice
F7D8
0908-001

7OM-1603
Chapter 4 : 3. Maintenance Spots
4-17
3.2.3 Magazine Base
Cylinder Connection Sections (4 locations for each)
Every 3 Months Lubrication (MOLYNOC GREASE AP1)
Required Time: 10 minutes
Zero Magazine Base #2 (Upper) and open the exchange position door.
Turn off the power.
Wipe off old grease from the cylinder connection sections located on the bottom
side of the magazine base with an oiled rag.
Apply new grease with a syringe.
Move Magazine Base #1 (Lower) to the middle magazine change position and
continue the maintenance for Magazine Base #1 from the magazine #1 door.
Take ample care not to leave any waste threads after cleaning.
Use No. 18 (green) nozzle.
No.18
A
B
VIEW A
VIEW B
Notice
Note
F7D9
1007-003