Error Code List.pdf - 第32页
AV131 ERROR CODE LIST 2.4 Errors D79EEC- 91-210-A 0 2.4- 9 1711 θ A a xis minu s o ve rrun in terl ock DESCRI PTIO N Th e m in u s o v er r u n i n t er l o c k of t h e θ A ax is w a s de te cte d . CAUSE θ A mi nus o v…

AV131
ERROR CODE LIST
2.4 Errors
D79EEC-91-210-A0
2.4-8
1705
Handle interlock
DESCRIPTION
Pushing H axis rotation wheel was detected.
CAUSE
H axis wheel detection (800C3:bit2) was detected while H axis was running.
SOLUTION
Please return H axis rotation wheel to original position.
NOTE
1706
Feeder float interlock (Left)
DESCRIPTION
Feeder float interlock of left part supply unit was detected.
CAUSE
ZL feeder float detection sensor (80041:bit1) was detected while ZL axis was running.
SOLUTION
Please confirm the setting of part supply unit left feeder.
NOTE
1707
Feeder float interlock (Right)
DESCRIPTION
Feeder float interlock of right part supply unit was detected.
CAUSE
ZR feeder float detection sensor (80001:bit6) was detected while ZR axis was running.
SOLUTION
Please confirm the setting of part supply unit right feeder.
NOTE
1708
Power failure interlock
DESCRIPTION
The power failure was detected while the machine was running.
CAUSE
Power failure (80580:bit7) was detected while the machine was running.
SOLUTION
Please turn power failure reset signal (805A0:bit7) on and off by the [Output check] of [Machine adjustment] to reset
power failure.
NOTE
1709
θH axis plus overrun interlock
DESCRIPTION
The plus overrun interlock of the θH axis was detected.
CAUSE
θH plus overrun (800C1:bit2) was detected while the θH axis was running. θH axis is located near mechanical
stopper.
SOLUTION
Please confirm θH plus overrun detection. Please confirm θH axis position.
NOTE
1710
θA axis plus overrun interlock
DESCRIPTION
The plus overrun interlock of the θA axis was detected.
CAUSE
θA plus overrun (80041:bit4) was detected while the θA axis was running. θA axis is located near mechanical
stopper.
SOLUTION
Please confirm θA plus overrun detection. Please confirm θA axis position.
NOTE

AV131
ERROR CODE LIST
2.4 Errors
D79EEC-91-210-A0
2.4-9
1711
θA axis minus overrun interlock
DESCRIPTION
The minus overrun interlock of the θA axis was detected.
CAUSE
θA minus overrun (80041:bit6) was detected while the θA axis was running. θA axis is located near mechanical
stopper.
SOLUTION
Please confirm θA minus overrun detection. Please confirm θA axis position.
NOTE
1712
V axis plus overrun interlock
DESCRIPTION
The plus overrun interlock of the V axis was detected.
CAUSE
V plus overrun (80082:bit0) was detected while the V axis was running. V axis is located near mechanical stopper.
SOLUTION
Please confirm V plus overrun detection. Please confirm V axis position.
NOTE
1713
V axis minus overrun interlock
DESCRIPTION
The minus overrun interlock of the V axis was detected.
CAUSE
V minus overrun (80082:bit2) was detected while the V axis was running. V axis is located near mechanical stopper.
SOLUTION
Please confirm V minus overrun detection. Please confirm V axis position.
NOTE
1714
X axis plus/minus overrun interlock
DESCRIPTION
The plus/minus overrun interlock of the X axis was detected.
CAUSE
X plus/minus overrun (80582:bit5) was detected while the X axis was running. X axis is located near mechanical
stopper.
SOLUTION
Please confirm X plus/minus overrun detection. Please confirm X axis position.
NOTE
1715
Y axis plus/minus overrun interlock
DESCRIPTION
The plus/minus overrun interlock of the Y axis was detected
CAUSE
Y plus/minus overrun (80582:bit4) was detected while the Y axis was running. Y axis is located near mechanical
stopper.
SOLUTION
Please confirm Y plus/minus overrun detection. Please confirm Y axis position.
NOTE
1716
ZL/ZR axes plus overrun interlock
DESCRIPTION
The plus overrun interlock of the ZL/ZR axes was detected.
CAUSE
ZL/ZR plus overrun (80582:bit7) was detected while the ZL/ZR ax was running. ZL/ZR axes is located near
mechanical stopper.
SOLUTION
Please confirm ZL/ZR plus overrun detection. Please confirm ZL/ZR axes position.
NOTE

AV131
ERROR CODE LIST
2.4 Errors
D79EEC-91-210-A0
2.4-10
1717
ZL/ZR axes minus overrun interlock
DESCRIPTION
The minus overrun interlock of the ZL/ZR axes was detected.
CAUSE
ZL/ZR minus overrun (80582:bit6) was detected while the ZL/ZR ax was running. A ZL/ZR ax is located near
mechanical stopper.
SOLUTION
Please confirm ZL/ZR minus overrun detection. Please confirm ZL/ZR axes position.
NOTE
1718
Ring IO communication interlock
DESCRIPTION
RING IO communication interlock was detected.
CAUSE
There is a possibility of coming off and the disconnection of the RING communication optical cable.
SOLUTION
Please confirm the RING communication optical cable.
NOTE
1720
Axis Moving interlock
DESCRIPTION
Direct start signal was off while axes was running.
CAUSE
Axis was not completed within its timing by the axis moving delay.
Direct start signal was off due to the power failure.
The direct start signal was off by the disconnection of cycle timer rotary encoder.
SOLUTION
Please confirm the axis where the error display. Please confirm axis movement is smooth, and confirm there is no
groan or Vibration.
Please release the power failure and restart operation.
Please confirm the state of the rotary encoder.
NOTE
1809
Servo ready off error
DESCRIPTION
The axis where the error occurred is not in NC ready status.
CAUSE
Ready input signal for the servo amplifier or NC board remains OFF.
SOLUTION
Check the condition of the servo amplifier, motor and NC/IO board.
NOTE
1811
(+) Overrun error
DESCRIPTION
Plus limit sensor for the axis where the error occurred was turned ON.
CAUSE
Plus limit sensor input was detected while the axis was moving (including starting to move) in the positive direction
for positioning or teaching.
SOLUTION
Close the error screen and move the axis in the negative direction. Or returning the axis to its origin also will do.
NOTE