1OM-1603 3-47 5. Stop, Interruption, and Restart of Operation : Chap.3 (4) Follow Steps (2) and (3) for all displayed steps. (5) When the "Check OK" appears for the component placement status in all the steps, …

1OM-1603
3-46
5. Stop, Interruption, and Restart of Operation : Chap.3
(3) When the components have been placed on the PCB, select the [Not Place]
button. When the components have not been placed on the PCB, select the
[Place] button.
(When the [Place] or [Not Place] button is pressed, the [Next Step] button
becomes available. When the [Next Step] button is pressed, the procedure
goes to the next step.)
F1C39
Note
(a) When an error occurs during the component placement, an "ERROR"
window appears.
Check the contents in the "ERROR" window and remove the cause
of the error. After that, perform a placement step recovery operation
again.
(b) To open the "Placement step Recovery" window again after the
"Product" window (the window that appears after the [PRODUCT]
button is pressed), follow the steps below.
•
Press the [Placement Recovery] button in the "Run Mode" window.
(Operation Sequence: [Product] Button → [Operation] Button →
[Run Mode] Button)
•
When "RECOVERY START ENABLE" is displayed in the
"Operator Message" eld, press the [START] button on the
operation panel.
1012-005

1OM-1603
3-47
5. Stop, Interruption, and Restart of Operation : Chap.3
(4) Follow Steps (2) and (3) for all displayed steps.
(5) When the "Check OK" appears for the component placement status in all the
steps, press the [START] button.
(The operation will be re-started).
F1C40
1012-005

1OM-1603
3-48
5. Stop, Interruption, and Restart of Operation : Chap.3
5.5 End of Automatic Operation
5.5.1 Stop of Automatic Operation
•
Stop of Automatic Operation by PCB Counter Stop Mode
When the "PCB Counter Stop Mode" function is used, the machine stops
automatically as soon as the counter reaches the specied number of PCBs to
be produced.
•
Stop of Automatic Operation with [All PCB out] Button
Press the [All PCB out] button in the status indication area (the upper area of
the operation window). The [All PCB out] button turns yellow.
After the machine has placed components on the PCB inside the machine, it
discharges the produced PCB and each device returns to its stationary position.
At this time, the [START] button on the operation panel extinguishes, the green
lamp of the light tower also goes out, and the automatic operation stops.
[All PCB out] Button
Status Indication Area (Upper Area of Operation Window)
F1C41
Reference
Refer to "5. Stop, Interruption, and Restart of Operation" in "Chapter 3" for the
other
ways to stop the machine.
1007-004