CM88Maintenace1 - 第133页

Page 1-95 REGULAR MAINTENANCE 1 Changing the Consumable Parts Every 1500 to 6000 Hours 8 . T urn off the servo switch. 9 . Open the rear center safety cover . 10 . Rotate the main axis motor once in the right direction, …

100%1 / 166
Page 1-94
Changing the Consumable Parts Every 1500 to 6000 Hours
3Y3C-E-MMD01-A09-03
R
E
L
E
A
S
E
T
R
I
P
O
F
F
O
N
R
E
S
E
T
To the next page
5. Turn off the main power, and on it to
start up again.
6. Open the engineer mode, and press
Machine
adjust
.
The Machine adjustment menu screen
appears.
7. Press Axis information .
The Axis information screen appears.
Page 1-95
REGULAR
MAINTENANCE
1
Changing the Consumable Parts Every 1500 to 6000 Hours
8. Turn off the servo switch.
9. Open the rear center safety cover.
10. Rotate the main axis motor once in
the right direction, and adjust it close
to 0 again, as 0. 1. 2. 3... 998. 999. 0.
Adjust it within 0 ± 10 pulse.
Adjust the encoder origin.
11. Press twice.
The “Main menu” screen reappears.
3Y3C-E-MMD01-A09-03
OFF ( )
ON ( )
SERVO
3Y3C-AI01
Reverse rotation
3Y3C-113P
3Y3C-EEn-MaAi-003
Right rotation
Page 1-96
Changing the Consumable Parts Every 1500 to 6000 Hours
2. Changing nozzle extension claws
Change claws at first and adjust position.
1. Loosen the bolts (M3) with a hexago-
nal wrench and change the nozzle
extension claws.
Set the nozzle extension claw inner as pos-
sible, not to contact with the elevating unit, and
make space between the claw and the nozzle
stopper of elevating unit.
3Y3C-E-MMD01-A09-02
Bolt
3Y3C-069P
3Y3C-178E