CM88Maintenace1 - 第153页

Page 1-115 REGULAR MAINTENANCE 1 Changing the Consumable Parts Every 1500 to 6000 Hours ∗ When the height does not match the standard value, adjust it loosening two screws on the upper position of the tape feeding cam fo…

100%1 / 166
Page 1-114
Changing the Consumable Parts Every 1500 to 6000 Hours
12. Press Axis information .
The “Axis information” screen appears.
13. Turn the coupling of main motor and
set “Main” on the “axis information”
screen to “556 (pulse)” (200degrees).
The tape feeding cam follower moves to the
lowest position by this operation.
3-C Checking the height of cam follower
1. Check the height of cam follower.
Check the interval of range between 0 mm and
0.03 mm by inserting the thickness gauge
between tape feeding cam follower and the top
face of inspection jig block, and so on.
3Y3C-E-MMD01-A10-03
To the next page
Thickness gauge
Tape feeding cam followerInspection jig block
3Y3C-077P
3Y3C-104P
3Y3C-EEn-Ma-001
3Y3C-EEn-MaAi-006
Page 1-115
REGULAR
MAINTENANCE
1
Changing the Consumable Parts Every 1500 to 6000 Hours
When the height does not match the standard
value, adjust it loosening two screws on the
upper position of the tape feeding cam follower.
a. Loosen the bolt holding the plate by hand.
b. Push up the plate.
c. Fix the bolt temporarily.
Tighten the bolts after adjustment.
2. Turn the coupling of main motor, and
set “Main” on the “Axis information”
screen to near “0 (pulse).”
“Main” must be within 0 ± 10 pulse.
3. Remove the inspection jig.
3Y3C-E-MMD01-A10-01
b
c
a
3Y3C-104P
3Y3C-078P
Page 1-116
Changing the Consumable Parts Every 1500 to 6000 Hours
1-7-7 Changing the Tape Discharging Hoses [3000 Hours]
Tape cut in the cutting unit is collected to the blower through the waste tape ejecting hose.
Waste tape ejecting hose on the main body and blower side is taped with a hose band. Loosen and
change these.
Check hoses so as they are not disconnected
by hand.
3Y3C-E-MMD01-A11-01
Hose band
BlowerMain body
3Y3C-079P 3Y3C-080P