Page 1-21 REGULAR MAINTENANCE 1 Check Every 24 Hours (Routine) 1-3-4 T ransfer Head : Cleaning the Head (after Operation) Remove any foreign bodies from the head with an air gun. ∗ Before starting operation, carry out “R…

100%1 / 166
Page 1-20
Check Every 24 Hours (Routine)
1-3-3 Blower : Casting off the Tape (after Operation)
Discharge the waste tape in the blower.
Tape corrector
Waste tape
Case
3Y3C-028P
3Y3C-E-MMD01-A03-01
Page 1-21
REGULAR
MAINTENANCE
1
Check Every 24 Hours (Routine)
1-3-4 Transfer Head : Cleaning the Head (after Operation)
Remove any foreign bodies from the head with an air gun.
Before starting operation, carry out “Return to
origin” in the “Machine adjustment menu”
screen. If they have already been done, this is
unnecessary.
1. Press
Machine
parameter
.
The Machine parameter screen appears.
2. Press Machine mainte .
The Machine maintenance screen appears.
3. Press Head mainte .
The Head maintenance screen appears.
3Y3C-E-MMD01-A03-03
To the next page
Page 1-22
Check Every 24 Hours (Routine)
4. Turn off the servo switch.
5. Open the rear center safety cover.
6. Remove the foreign bodies from the
head with the air gun.
Be careful not to leave the removed foreign
bodies on recognition lighting.
7. Close the rear center safety cover.
8. Turn on the servo switch.
9. Press
UNLOCK
and Main axis step .
Main axis moves by steps.
10. After that, repeat the procedures 4 to
9 to remove the foreign bodies from
the transfer head.
OFF ( )
ON ( )
SERVO
3Y3C-AI01
Transfer head
3Y3C-029P
3Y3C-AG01
Rear side
Main axis
3Y3C-131E
OFF ( )
ON ( )
SERVO
3Y3C-E-MMD01-A03-01