Page 1-35 REGULAR MAINTENANCE 1 3Y3C-E-MMD01-A04-01 4. Select the nozzle. ∗ Several nozzles can be selected. Pressing can also select all nozzles at once. ∗ Pressing exist for “Visual check” stops the machine for each he…

Page 1-34
5. Checking Nozzle Settings
After removing and setting nozzles, check the arrangement of them.
The machine has the function to find the nozzle which may be arranged wrong. This is done by
recognizing the nozzle after nozzle setting, and judging that the nozzle matches to that arrange-
ment by the diameter. At the same time, the nozzle appearing on the screen can be checked one
by one visually.
When only specified nozzles are removed and set, “Checking nozzle settings” can be omitted.
1. Close the rear center safety cover.
2. Press Nozl set chk .
3. Turn on the servo switch.
To the next page
3Y3C-AG01
Check Every 140 Hours (Once a Week)
3Y3C-E-MMD01-A04-01
OFF ( )
ON ( )
SERVO

Page 1-35
REGULAR
MAINTENANCE
1
3Y3C-E-MMD01-A04-01
4. Select the nozzle.
∗ Several nozzles can be selected.
Pressing can also select all
nozzles at once.
∗ Pressing exist for “Visual check” stops the
machine for each head, and enables to see the
nozzle on the screen.
5. Press
UNLOCK
and Nozl set chk .
• “Checking the nozzle” appears.
∗ The head No. and name of nozzle to check are
displayed.
For the wrong nozzle arrangement, following screen is displayed.
6. Check “Head No.” and “Nozzle.”
∗ When the nozzle check is not over, press
UNLOCK
and Yes to continue checking.
Check Every 140 Hours (Once a Week)
All nozzle s
elect
To the next page.

Page 1-36
3Y3C-E-MMD01-A04-01
The nozzle arrangement may be wrong
8. Press .
∗ Select the nozzle which may be wrong.
9. Press
UNLOCK
and Nozzle Extend .
• “Nozzle Extend” is carried out.
10. Press
UNLOCK
and Main axis step .
• The main axis moves by step.
∗ Continue the operation by step until the head of
nozzle which may be wrong comes to the “Chip
pickup” station.
11. Turn off the servo switch.
12. Open the rear center safety cover.
13. Check the nozzle arrangement, and
change nozzles if an error is found.
∗ If the arrangement is changed, carry out “Checking nozzle settings.”
Nozzle select
OOO
3
2
1
Check Every 140 Hours (Once a Week)
After checking, following screen appears.
7. Press .
∗ If wrong nozzle arrangement is not found,
continue to carry out “Nozzle exchange teach.”
∗ When the nozzle arrangement may be wrong,
go on to the procedure 8.
3Y3C-EEn-MpMmNm-006
3Y3C-AI01
OFF ( )
ON ( )
SERVO