D1_ServiceManual_e.pdf - 第20页

1 Installation 1-12 Blank Page

100%1 / 58
1 Installation
1-11
Sequence of Sending PC board (SMEMA Interface spec.)
When component placements have been finished, the machine becomes ready to send out the PC
board.
The machine starts to send out signals through BOARD AVAILABLE line to the post-process and the
conveyor is activated when the machine receives signals through MACHINE NOT READY line from
the post-process under the condition described in 1.
The board stopper will be activated after the arrival sensor has been deactivated and the time set at
WAIT-1 has passed.
The machine stops to send out signals through BOARD AVAILABLE line and the conveyor is
deactivated after the board stopper was activated and a certain time (preset in TIMER) has passed.
If the conveyor will not be deactivated within 10 seconds after it was activated, an error
[CONVEYOR TROUBLE] will result.
If the machine continues to receive signals through MACHINE NOT READY line after the conveyor
was activated and the time set at WAIT-16 has passed, an error [I/F TROUBLE (POST-PROCESS)]
will result
Pressing START button restarts the operation paused by the error.
MACHINE NOT READY
BOARD AVAILABLE
MACHINE NOT READY
CONVEYOR
ARRIVAL SENSOR
BOARD STOPPER
PLACEMENT
ON
TIMERWAIT-1
END
RUN
ENDRUN
OR
PLACEMENT
BOARD AVAILABLE
1 Installation
1-12
Blank Page
2 Periodical Checks
2-1
2
Periodical Checks