SIPLACE Line Computer UNIX - 第357页
User Manual Line Computer UNIX 12 Production Tools / Station and Li ne Conf iguration Software Vers ion 502.xx 10/2000 Issue 12.1 Configuration Editor 355 I t I I Generating a new configuration: ● E nter new stat ion nam…

12 Production Tools / Station and Line Configuration User Manual Line Computer UNIX
12.1 Configuration Editor Software Version 502.xx 10/2000 Issue
354
I
t I I
12.1.1 Starting the Configuration Editor
To be able to change or generate a station configuration, the steps described below have to be performed first.
● Click on SERVICES -> Station Configuration on the desktop menu bar.
The FSB containing the directory "master data:Stationen" is opened.
The list of the configured stations is displayed in the FSB.
Changing existing configurations:
● Select station "xx.st" and confirm with OK (or select station directly by double-clicking).
The main window of the Configuration Editor, the Structure Editor is opened (see
Fig. 12.1.1).
NOTE
Problems may be encountered if an existing configuration is changed on the basis of which a set-up
has already been generated (consistency of set-up and configuration data). If, for example, an nozzle
changer, which was defined in the station’s set-up data for the assembly of a particular PCB, is remo-
ved from the configuration of the station, it is no longer possible to select the job for the assembly of
this PCB (see chapt. 14).

User Manual Line Computer UNIX 12 Production Tools / Station and Line Configuration
Software Version 502.xx 10/2000 Issue 12.1 Configuration Editor
355
I
t I I
Generating a new configuration:
● Enter new station name "xx.st" and confirm with OK (or RETURN).
The FSB containing a listing of the machine types available for selection opens
(directory "master data:ST-Bibliothek").
NOTE
The station name may comprise max. 20 characters including the suffix ".st".
Some characters must not be used for the name, see chapt. 2, section 2.3 in this connection.
● Select machine type of the station entered and confirm with OK (or select machine type directly
by double-clicking).
The main window of the Configuration Editor, the Structure Editor is opened (see
Fig. 12.1.1).

12 Production Tools / Station and Line Configuration User Manual Line Computer UNIX
12.1 Configuration Editor Software Version 502.xx 10/2000 Issue
356
I
t I I
12.1.2 Main Window of Configuration Editor (Structure Editor)
In the Structure Editor the maximum permitted configuration of the selected machine type is shown.
Fig. 12.1.1 Structure Editor (Machine Type "SIPLACE F5)
menu bar
fixed, non-changeable
machine option
allocated (set up) machine
option
unallocated machine
option (may be set up)
graphical display of the
station
selected, allocated machine optionlocation
display area