00198355-01_AI_Arbitrary_Flex_JEDEC_tray_SOKO_en - 第18页

2 Installation of Arbitrary JEDEC Tray 2.3 Installation Procedure Assembly Instructions E by SIPLACE Arbitrary Flex JEDEC tray SOKO 04/2017 18 ► Reassemble the respective nozzle magazines but with the shown restrictions.…

100%1 / 20
Assembly Instructions E by SIPLACE
Arbitrary Flex JEDEC tray SOKO 04/2017
2 Installation of Arbitrary JEDEC Tray
2.3 Installation Procedure
17
Fix "shim cover nozzle station" [03108393-xx], and "shim nozzle station" [03108395‑xx] onto
the "mounting block left 2B" [03112942‑xx], and "mounting block right 2B
FLEX" [03112578‑xx].
Check gap with the "height measuring block" [03118537-xx]. (The pictures above are a refer-
ence on how the gauge is used to measure the required height).
Use the feeler gauge to measure the gap and determine the number of
"ShimsNC" [03108395‑xx] to be used.
Once complete, fasten with a M3x8 countersunk screw.
Reassemble the initial "Magazine holder" [03103612-xx] previously removed from location 2.1
with four M5x20 cap screws onto this new location 2.2.
2 Installation of Arbitrary JEDEC Tray
2.3 Installation Procedure
Assembly Instructions E by SIPLACE
Arbitrary Flex JEDEC tray SOKO 04/2017
18
Reassemble the respective nozzle magazines but with the shown restrictions.
NOTICE
Validity of Single Nozzle Magazine
Mounting of "Single nozzle magazine" [03109863-xx], in location 2.2 is only valid for "E-by
SIPLACE FLEX" machines without flip chip camera, at the positions shown above.
Additional Restrictions:
This SOKO is applicable only for E by SIPLACE - FLEX RV12 variant only.
The combine height for JEDEC tray + components should not be higher than 15mm.
Single nozzle magazine [03109863-xx], it NOT recommended for use in location 2.2.