YSH20_Ope_E - 第108页
2-51 2 asic operation n W afer tray components 6 Set the "F eeder T ype" parameter . Select "W afer TC" from the drop-down list. [Parts] - [Basic] screen "Feeder T ype" parameter "Fee…

2-50
2
asic operation
n
Tape components
6
Set the "Tape Type" and "Feeder Type" parameters.
Double-click the "R. Tape Type" parameter field and select a desired tape type from the drop-down list.
[Parts] - [Basic] screen
Example of tape feeder
"R Tape Type"
24227-H0-00
c
7
Set the "Pitch Index" parameter.
Double-click the "F. Pitch Index" parameter field and select a correct feed pitch from the drop-down list.
n
NOTE
This parameter does not appear when "Reference of feeder pitch" is set to "Feeder setup".
Parts screen
"Pitch Index" parameter
"F. Pitch Index"
24228-H0-00
TIP
For more details, refer to the SS feeder user's manual.

2-51
2
asic operation
n
Wafer tray components
6
Set the "Feeder Type" parameter.
Select "Wafer TC" from the drop-down list.
[Parts] - [Basic] screen
"Feeder Type" parameter
"Feeder Type"
24232-H0-00

2-52
2
asic operation
5.2 Operation check
After installing the feeders and making their settings, check to see if they operate correctly.
n
Tape feeder
1
Open the feeder screen.
Press the [Unit] button and then select the [Feeder] tab to open the feeder screen.
2
Select the feeder.
Select the feeder to check the operation.
TIP
You can select a feeder in the feeder layout diagram or from the feeder list.
Feeder screen
Selecting the feeder
Feeder list
Feeder layout diagram
24229-H0-00
3
Check the feeder operation.
Press the [Feed] button on the lower right of the screen to check that the tape is fed at the correct
pitch.
Feeder screen
Checking the operation
[Feed] button
24230-H0-00
n
NOTE
When a feeder with a pitch of 4mm or more is installed, check the top component and its position.