YSH20_Ope_E - 第133页

3-22 3 Starting and ending pr oduction 3.7 Fiducial T he [Fiducial] tab screen shows the recognition results of fiducial marks such as "Board, Bloc k", "2 Point Local" and "P oint" fiducial …

100%1 / 141
3-21
3
Starting and ending production
3.5 Alignment
The [Alignment] tab screen shows the offset amount of each head calculated from the recognition results
obtained during automatic operation, as well as error numbers.
Monitor: Alignment
24313-H0-00
Head No.
Shows the head No. used in the machine. The recognition results of the head No. used in the sequence that starts from
the current pickup are displayed. Note that the display is made after the camera image recognition has completed.
Parts No.
Shows the number of the component picked up by the head and recognized with the camera.
Feeder Set No.
Shows the feeder set number of the component picked up by the head and recognized with the camera.
X, Y, R
Displays the offset amount of each head calculated from the recognition results obtained during automatic operation.
This offset is the positional deviation from the center of the nozzle.
Error No.
Shows an error number when the head fails to recognize a component.
3.6 Retry
The [Retry] tab screen displays the history or the past 100 errors.
Monitor: Retry
24314-H0-00
3-22
3
Starting and ending production
3.7 Fiducial
The [Fiducial] tab screen shows the recognition results of fiducial marks such as "Board, Block", "2 Point Local"
and "Point" fiducial marks.
Monitor: Fiducial
24315-H0-00
Align X, Y, R
Shows the difference between the recognition results and the board data input values, by plus or minus values.
Align Ratio
Shows the rate of expansion of the board, calculated by using the X, Y and R offset values.
Result
Shows the recognition results as a "Pass" or "Unfinished ". The "Unfinished" message changes to "Pass" after the mark has
been recognized successfully.
3.8 Badmark
The [Badmark] tab screen shows the recognition results of badmarks such as "Board, Block" and "Local"
badmarks.
Monitor: Badmark
24316-H0-00
X, Y
Shows the board data input values (by taking block offset amount into account).
Result
Makes an "OK" or "NG" decision based on the badmark recognition result.
OK : Work is performed when no badmark is recognized.
NG : Work is not performed when a badmark is recognized.
3-23
3
Starting and ending production
3.9 Pick Pos. (Pickup position offset)
This screen appears when the pickup position offset function is used. This screen shows how the pickup
position of the target component was corrected or offset. When the amount of offset in either the X or Y
direction crosses into a warning zone or error zone, the color of that row changes in real-time. The monitor
display color is shown below.
n
Display color
Color of row Status Description
Yellow Warning
Exceeds warning level figure for each nozzle data set in pickup position offset
specifications.
Red Error
Exceeds error level figure for each nozzle data set in pickup position offset
specifications.
n
NOTE
Numerical values for warning level and error levels set in the pickup position offset specifications are values
determined by the supervisor (administrator).
Monitor: Pick Position
24317-H0-00
No.
Displays the component No. (Parts screen data No.).
Set No.
Displays the feeder set No.
Parts Name
Displays the component name.
Tape Type
Displays the type type.
X (mm), Y (mm)
Displays the amount of pickup position offset after recognition. The figure shown is the amount of error from the nozzle
center position towards the X-direction and Y-direction.
Pick Rate (%)
Displays the component pickup rate of the nozzle for which the pickup position offset function is on (enabled).
Count
Displays the number of components that were picked and placed by the nozzle for which the pickup position offset
function is on (enabled).
[All Reset] button
This button clears and resets pickup position offset data for all components shown on the monitor.
[Current Reset] button
Clears and resets pickup position offset data for a component selected from among components shown on the monitor.