YSH20_Ope_E - 第139页
A-1 Appendix A1. Specifications n YSH20 specifications Item Specifications Operating ambient temperature Function guaranteed: 18 to 30°C Accuracy guaranteed: 24 ± 2°C Operating ambient humidity 45 to 85% (no condensation…

A-1
Appendix
A1. Specifications
n
YSH20 specifications
Item Specifications
Operating ambient temperature
Function guaranteed: 18 to 30°C
Accuracy guaranteed: 24 ± 2°C
Operating ambient humidity 45 to 85% (no condensation), optimal range: 50 to 60%
Noise level Under 78dB
Power requirement (voltage and frequency) 3-phase AC 200/208/220/240/380/400/416 V ± 10%, 50/60 Hz
Average power consumption 1.42kW
Power cable (conductor cross-section area) 5.5 mm
2
or more
Overvoltage category *
1
Category III
Pollution degree *
1
Degree 2
Supply air pressure *
2
0.50MPa or more
Air flow rate *
6
FF head
Average 230 to 410Nl/min, maximum momentary flow rate: 430Nl/min
4M head Average 20Nl/min, maximum momentary flow rate: 28Nl/min
Board transport height *
3
900 mm ± 10 mm
Data
Number of mounting points *
4
10,000 points
Number of part types 255 types per board
Number of fiducial marks *
5
128 sets per board
*1: Conforms to IEC60664-1.
*2: Clean, dry air passed through an air dryer and filter.
*3: Distance from the floor surface to the upper surface of conveyor belt.
*4: Decreases with the number of boards, blocks and fiducial marks.
*5: When using 2-point fiducial mode.
*6: Average values depend on the load.
c
Conveyor's board sensors may fail to detect a production board if it has a slit or cutout.
n
NOTE
For more detailed information not listed above, please refer to specification sheets.

S-1
Index
A
Axis configuration 1-19
Board production
Ending production 3-11
Pre-operation check 2-19
Resuming operation 3-6
Starting production 3-1
Starting the machine 2-20
C
CE marking i
Component supply section 1-14
Conveyor unit 1-17
Conveyor width 2-13
[Convey-out stop] button 3-11
[Cycle Stop] button 3-11
Data input unit 1-7
Dipping station 1-6
Dummy feeder iv
E
Emergency stop
Canceling emergency stop 2-1
Error
Clearing an error 2-2
Errors and troubleshooting 2-3
Expander unit 2-45
[Feeder Setting] button 2-16
Feeder setup section 1-14
H
Head assembly 1-9
4M head 1-10
F head 1-10
K
Keyboard 1-7
Machine main unit 1-1
Names and functions of major parts 1-1
Magazine position selector switch 1-4
Magazine size attachment 1-16
Manual feeder operation 2-16
Manual head operation 2-15
Manual I/O operation 2-17
[Monitor] button 3-13
Mouse 1-7
Multi-vision camera 1-11
Muzzle plate 1-2
N
Nozzle station 1-13
Nozzle types 1-12
Nozzles for F head 1-12
Operation panel 1-7
[READY] button 2-1
Operation panel buttons 1-8
[ACTIVE] button 1-8
[EMERGENCY STOP] button 1-8
[ERROR CLEAR] button 1-8
[READY] button 1-8
[RESET] button 1-8
[START] button 1-8
[STOP] button 1-8
Operation screen 2-8
Menu button area 2-8
Status area 2-8
Operation speed 3-3
[Operator] button 2-21
P
Password 2-21
Pick Rate Warning 3-24
Pickup position offset 3-23
Pitch movement correction 2-44
Power switch 1-3,2-20
Turning power off 3-11
Pressure gauge 1-2
Production monitors 3-13
R
Return-to-origin 2-20
S
Safety ii
Safety cover 1-2
Safety message vii
Setup screen 2-11,3-2
[Check Nozzles] button 3-3
[Feed Bulk] button 3-3
[Required Nozzles] button 3-3
[Required Parts] button 3-3
Signal light 1-2
Specifications A-1
T
Tape feeder
Disposing of used top tape 3-4
Operation check 2-52
Setting a tape feed pitch 2-30
Settings on the machine side 2-48
Setting the tape 2-25
U
Unit screen 2-13
W
Wafer pallet 2-35
Wafer tray changer 2-35
Warm-up 2-22
[Warm Up] button 2-22
Warning labels xi
"watch-and-wait" mode 3-26
