Nordson_EFD_781RC_Operating_Manual

781RC MicroMark Recirculating Spray Marking System Operating Manual Electronic pdf files of Nordson EFD manuals are also available at www.nordsonefd.com ™

100%1 / 18
781RC MicroMark Recirculating Spray Marking System
Operating Manual
Electronic pdf files of Nordson EFD
manuals are also available at
www.nordsonefd.com
Contents
781RC MicroMark Recirculating Spray Marking System
2 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Contents ..........................................................................................................................................................................2
Safety Warnings ..............................................................................................................................................................3
Equipment Misuse Hazard ...........................................................................................................................................3
Personal Protective Equipment ...................................................................................................................................3
Fluid Compatibility .......................................................................................................................................................3
Fill Level .......................................................................................................................................................................3
User’s Responsibility ...................................................................................................................................................3
Tipping and Dropping Hazard .....................................................................................................................................4
Tubing Safety ...............................................................................................................................................................4
Preventive Maintenance ..............................................................................................................................................5
Specifications ..................................................................................................................................................................6
Introduction .....................................................................................................................................................................7
How the System Operates ...........................................................................................................................................7
Before You Begin Power Input Options ..................................................................................................................7
Setup ...............................................................................................................................................................................8
Initial 781RC Installation / Setup Procedures..................................................................................................................9
Recirculation System Startup Procedures after Prolonged Periods of Downtime ........................................................11
Calibration Feature ........................................................................................................................................................12
Maintenance and Cleaning ............................................................................................................................................12
General Cleaning .......................................................................................................................................................12
Disposal of Discarded Wetted Materials ...................................................................................................................12
Pump Maintenance and Cleaning (Fluid Side) ...........................................................................................................13
Pump Cleaning (Motor Drive Side) ............................................................................................................................14
Valve Cleaning ...........................................................................................................................................................14
Part Numbers ................................................................................................................................................................14
Replacement Parts .......................................................................................................................................................15
Troubleshooting Guide ..................................................................................................................................................16
Safety Warnings
Equipment Misuse Hazard
GENERAL SAFETY Any use of the reservoir and related accessories not consistent with that
described in this manual, such as modifying or removing parts, over-pressurizing, using incompatible
fluids and chemicals, or using worn, damaged, or incompatible parts can cause them to rupture,
resulting in serious bodily injury, including fluid splashed in the eyes or on the skin, or fire, explosion, or
other property damage. NEVER alter or modify any part of this equipment, as doing so may cause it to
malfunction. CHECK all system components regularly and replace any worn or damaged parts with only
EFD supplied or approved parts. BE SURE that all dispensing equipment and accessories are rated to
withstand the maximum operating pressure of the reservoir.
Personal Protective Equipment
Wear all protective eyewear, gloves, clothing, and a respirator as recommended by the manufacturer of
the fluid used.
Fluid Compatibility
BE SURE that all fluids, including their vapors, contained in the reservoir are compatible with all
materials on the wetted materials list on page 6 of this manual. Read the fluid manufacturer’s literature,
including the MSDS (Material Safety Data Sheet), and observe all warnings before pouring the fluid into
the reservoir.
Fill Level
DO NOT overfill the reservoir. The recommended maximum fill level is 38.1 mm (1.5") below the top of
the liner.
User’s Responsibility
It is the responsibility of the user to ensure the 781RC system is installed in a manner that complies with
all local and national jurisdictional requirements.
781RC MicroMark Recirculating Spray Marking System
3www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.