00195655-04_SM_X-Series_FSE_en - 第61页
Service Work 3.3.7 Replacing the Y Axis Scale [03005490-xx] Gantries Service Manual (internal ver sion) SIPLACE HF and X Series 61 Checking the adhesive device Overview 1. Press roller 2. Adhesive device (viewed from bel…

Service Work
Gantries 3.3.7 Replacing the Y Axis Scale [03005490-xx]
60 Service Manual (internal version) SIPLACE HF and X Series
3.3.7
3.3.7 Replacing the Y Axis Scale [03005490-xx]
Replacing the Y Axis Scale [03005490-xx]
Please also observe the technical information "Overview of Scales and Read Heads" [DE: TI2014-
05D11] [EN: TI2014-05E11].
Tools
▪ Scale - adhesive device set (HF/ X-Series) [00377013-xx]
▪ Double-sided adhesive strip - Scotch Y-9460 [00343774-xx]
▪ Protective sheet 12mm wide [00378511-xx]
▪ Ethanol
▪ Protective gloves (provided with set)
Prior checks
Casting marks on the incremental encoder
► You must set the exact height to the scale.
► Align the incremental encoder, using the two casting
marks (arrows), which mark the read area.
► Tighten the fastening screws.
► Reconnect to the electricity supply (X15 or X24).
CAUTION!
Check how the cables are run!
Make sure that the axes can be moved without damaging
the cables.
Fasten the cables with cable ties.
► Move the gantry into the end stopper and check that
the bumper does not come into contact with the ca
-
ble.
► Check whether there is a drill hole (1) on the machine
base. If not, you will need to mark the start and end
positions (2) of the old scale (3) with a scribing iron.
► Check the length of the installed scale. If this is short
-
er than the replacement scale, you will need to fix the
new scale from position 1 or 3 onwards with adhe
-
sive.
2
1
3
2

Service Work
3.3.7 Replacing the Y Axis Scale [03005490-xx] Gantries
Service Manual (internal version) SIPLACE HF and X Series 61
Checking the adhesive device
Overview
1. Press roller
2. Adhesive device (viewed from below)
3. Fixing pin
4. Screw
► Check the setting of the press roller (1).
► Place the adhesive device (2) and the press roller flat
onto the table.
► Place a plastic sheet (0.2 mm thickness) under the
press roller. Make sure that the press roller lies flat on
the plastic sheet.
CAUTION!
Set the fixing pin correctly
The fixing pin for the scale must be set so that it touches
the screw (4) and can guide the scale, without the latter
slipping out.
1
4
3
2
1. Y axis incremental encoder
► Loosen the three screws fastening the incremental
encoder (1) of the Y axis and carefully lift off the in
-
cremental encoder.
► Temporarily fix the incremental encoder to a suitable
place (e.g. with adhesive tape to the back of the gan
-
try).
WARNING!
STRONG MAGNETIC FIELDS!
Always follow the special safety instructions when work
-
ing in the vicinity of powerful magnetic fields, caused by
the permanent magnets (3).
1

Service Work
Gantries 3.3.7 Replacing the Y Axis Scale [03005490-xx]
62 Service Manual (internal version) SIPLACE HF and X Series
Removal
Installation
► If necessary, remove the side covers on the machine,
for better accessibility (4) .
► Move the gantries into the position which allows you
best access.
► Use the chisel to lever the scale off the right side (1)
of the machine base.
CAUTION!
Make sure that you do not damage the drilling (2).
► Remove the scale (3).
► Use the chisel to remove any adhesive residues from
the contact surface. Wipe the contact surface clean
with a multiflex pad.
► Clean the contact surface with ethanol. The surface
to be fixed down must be clean and free of grease.
1
4
2
3
4
► Move the gantries to the position which gives you
best access to the whole scale.
► Wear protective gloves.
► Attach the adhesive strip to the new scale and then
return this to the packaging.
► Pull the packaging slightly back.
► Pull the transparent cover strip approx. 5 cm off the
adhesive strip on the back of the scale.
CAUTION!
Make sure the scale is not bent or rubbed against any
parts.
Also make sure that it is not scratched!
► Fit the scale (1) so that the pin (2) of the scale slides
into the hole.
1
2