00195655-04_SM_X-Series_FSE_en - 第91页
Service Work 3.5.2 Settings the C&P20 (FSE) Jaws C&P20 Placement Head Service Manual (internal ver sion) SIPLACE HF and X Series 91 Fitting the setting gauge Moving the Z axis arms out ► R o t a t e t h e s t a r…

Service Work
C&P20 Placement Head 3.5.2 Settings the C&P20 (FSE) Jaws
90 Service Manual (internal version) SIPLACE HF and X Series
Dismantling the dead indexing plate
1. 2 segments without nozzles or dead indexing plate
► Remove the nozzles and dead indexing plates from
two neighboring segments.
Dismantling the Z axis cover
1. Z axis drive cover
► Remove the cover on the Z axis drive (1) (2 screws
on the raceway and one screw on the Z motor unit).
► Fasten the Z motor unit back into place with the orig
-
inal screw. This ensures that the Z motor unit is in the
exact position required for setting the jaws.
Screw fastening the jaws
1. Screw fastening the jaws
► Carefully loosen the screw fastening the jaws (1) so
that the jaws can be moved on the arms of the Z axis
(can be moved to the left and right).
Do not fit the gauge yet!
► Clean the raceway contact surface and the setting
gauge with a lint-free cloth.
NOTICE!
Always clean the contact surfaces before fitting the set
-
ting gauge!

Service Work
3.5.2 Settings the C&P20 (FSE) Jaws C&P20 Placement Head
Service Manual (internal version) SIPLACE HF and X Series 91
Fitting the setting gauge
Moving the Z axis arms out
► Rotate the star so that the jaws/arms of the Z axis are
centered between the two segments, without dead in
-
dexing plates.
► Move the Z axis out without the segment.
Fitting the setting gauge
► Place the jaw gauge on the raceway, ensuring that
the jaws lie flat on the contact surfaces.
Press the jaw gauge against the holes drilled in the
raceway, so that the centering pins engage with the
relevant holes.
Fixing the setting gauge with the M2.5x12 mm screws
► Fasten the gauge with the screws (1) from the service
kit (M2.5x12 mm).
NOTICE!
Do not use the original raceway screws to fix the setting
gauge! These are too short and could damage the thread!

Service Work
C&P20 Placement Head 3.5.2 Settings the C&P20 (FSE) Jaws
92 Service Manual (internal version) SIPLACE HF and X Series
Setting the jaws
► Make sure that the Z axis is located between the two segments without dead indexing plates and
that you can see the Phillips screw.
Fitting the setting gauge onto the C&P20 head
NOTICE
If
► The side stopper (stop pin) of the gauge presses against the jaws so that these can not be
moved.
Procedure: if it is not possible to push the 0.04 feeler gauge between the jaws and the stop
pin of the gauge, make sure that the jaws lie flat against contact surfaces 2a and 2b of the
gauge.
► The jaws can not be pressed against the side stop (stop pin) of the gauge.
Procedure: In this case, push the jaws as far as possible towards the stop pin. Do not push
the jaws with force against the stop pin of the gauge.