00194474-0702_AI_HeadReconfig_X_605_DE EN - 第150页
2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits Head Reconfiguration Kits 07/2010 Edition 150 03016216- Hose/C&P20 pressure control va lve 03016217- Hose/C&P20 holding circuit 03016218- Hose/…

Head Reconfiguration Kits 2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits
07/2010 Edition
149
2
2
00119761- 6-segment C&P head, reconfig. kit, X-series
03041229- 6-segment Collect&Place head DLM3 cpl.
(previous version: DLM2-6 revolver head complete: 00367020-)
03018637- C&P component camera, (type 29), 27x27, digital
03041494- Parts set for ReConfig X-series/DLM2
03037629- Upgrade kit /DLM2 16 bit
03019066- BOARD/ DLM-X head adapter
00344488- SM board, modular
00353445- SDS120/2.5S1 servo amplifier
03002141- SDS60/3Z1 servo amplifier
03002142- SDS60/1D1 servo amplifier
00324407- Spacer bolt, type B i/a-M3x7-ST
03004333- DLM ribbon cable set
03005194- Cable support, DLM2 head adapter
03011721- DLM2 fixing set for HF
03006775- DLM2-HF hoses
03003719- Container
03037822- Axis, KSP-A363 Smart Drive (2 x VC03)
03011690- DLM2 template
03003719- Container
03009178- TwinHead packaging
03012054- Component camera packaging, stationary, P&P
03029045- Packaging, complete, C&P20
00194474- Retrofit instructions: head reconfig. kits, X-series
00119762- 20-segm. C&P head, reconfig. kit, X-series
03008827- C&P20 placement head
03040940- Parts set for ReConfig X-series/C&P20
03009387- Upgrade kit /C&P20 for X-series
03012097- Cable set /C&P20
03002870- Board / C&P20 head adapter
03005195- Cable support, P&P head adapter
03002397- Card /DC-DC converter, DP
00353445- SDS120/2.5S1 servo amplifier
03002143- SDS60/2.5Z1 servo amplifier
00095021- DIN912 M4x14 - 8.8
03011720- Sealing for head support plate / VHS

2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits Head Reconfiguration Kits
07/2010 Edition
150
03016216- Hose/C&P20 pressure control valve
03016217- Hose/C&P20 holding circuit
03016218- Hose/C&P20 return cylinder
03043753- Nozzle station, complete, C&P20
03045404- Hoses for nozzles on station
03045754- Fine flow restrictor GRO-QS-4-LF
03037821- Axis, KSP-A363 Smart Drive (1 x VC03)
03011694- VHS template
03039042- Component reject bin up to 6x6
03009178- TwinHead packaging
03012054- Component camera packaging, stationary, P&P
00066176- Packaging for 6/12 placement head
03038412- Component camera packaging, C&P 6/12 digital
03055787- Nozzle station, complete C+P20
03051467- Hoses, nozzle station / with valve
03073841- FHE retrofitting kit for X-series
03073256- Extension straight TX20
00194474- Retrofit instructions: head reconfig. kits, X-series

Head Reconfiguration Kits 2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits
07/2010 Edition
151
2.4 Safety instructions
WARNING
The safety instructions from the “Operational safety” chapter of the user manual and servicing in-
structions take precedence over these instructions. 2
SIPLACE placement machines are supplied with main power voltage.
Consequently parts of these systems carry dangerous voltages! This voltage is present at certain
modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death or severe injury, and considerable damage to equipment.
BEFORE starting any work, shut down the operating system correctly, then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve in the machine
base and vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the vicinity of the linear motors, as described
in detail in the "Special safety instructions for working in the vicinity of strong magnetic fields"
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or other standards and special safety
rules applicable in your country.
Pay attention to the information concerning residual voltages in the Operational Safety chapter.
Follow the ESD regulations as described in the operational safety section of the operating
instructions.
During the retrofit, always secure the machine to prevent access by other people and to prevent
it being switched on again. The procedure is described in the “Locking the machine…” section of
the user manual.
Working with the SITEST program further increases the risk of accident.
The SITEST program must only be used by authorized and trained personnel.
2
2.4.1 Definitions
2
Please note 2
2
2
2
Caution 2