Service Work C&P12 Placement Head Replacing the Co mponent Camer a (D Series) [03014449 -xx] 152 Serv ice Manual SIPLACE D4 Installation See also: J 6.3.1 Calibrating the C&P Head and Cameras [ J  221] X Make su…

100%1 / 268
Service Work
Replacing the Component Camera (D Series) [03014449-xx] C&P12 Placement Head
Service Manual SIPLACE D4
151
4.5.3 Replacing the Component Camera (D Series) [03014449-xx]
Removal/Installation
The component camera must be replaced as a
complete unit. This consists of the lens system,
camera, amplifier, illumination planes and
"illumination controller" board.
Article numbers
SST28 [03014449-xx]
SST29 [03018637-xx]
NOTE:
You may need to completely dismantle
the front part of the head (4), so that the
components can be more easily
accessed.
ATTENTION: Do not damage the
fixture clips!
To disconnect the component and PCB
camera connections, you need to open
the fixture clips by applying pressure to
the side of the connector.
X For details see section (4.5.22 Press
Fit Connections with Fixture Clips on
the Vision Board (D Series)
J
196 )
X Disconnect the flat ribbon cable holders (5) at
the Vision board (7) of the gantry head
distributor.
X Pull both flat ribbon cable connectors (6) off
the Vision board of the gantry head
distributor (2).
X Loosen the four screws (3) holding the
component camera.
X Carefully lift off the component camera (1).
Service Work
C&P12 Placement Head Replacing the Component Camera (D Series) [03014449-xx]
152 Service Manual SIPLACE D4
Installation
See also:
J
6.3.1 Calibrating the C&P Head and Cameras [
J
221]
X Make sure that all contact surfaces are clean.
X Place the holes in the camera on the parallel
pins (4).
X Carefully position the camera on the C&P
head, until the camera plinth lies flat on the
contact surface of the front part of the C&P
head.
X Fix the camera in place with the four screws
provided (3).
X Fit the front part of the C&P head (4).
X Reconnect the flat ribbon cables (6) to the
Vision board (7) of the gantry head distributor.
X Refit the flat ribbon cable strain relief (5). This
reestablishes the ground connection.
X Start the machine.
X Use the SITEST program to calibrate the C&P
head.
Service Work
Replacing the Intermediate Distributor [00330648] C&P12 Placement Head
Service Manual SIPLACE D4
153
4.5.4 Replacing the Intermediate Distributor [00330648]
Removal/Installation
The following supply voltages and signals are routed by the intermediate distributor to the individual
placement head modules or to the head board:
X Please observe the ESD regulations for the
following work and use an ESD ground strap.
X Loosen the four fastening screws and remove
the cover (1), by pulling these off the 4 snap
fasteners.
X Undo the four spacer bolts (3) and tilt the
intermediate distributor (2) a little.
3
3
1
3
2
4-41: Position of the sockets
Legend
1. Front of the intermediate distributor
2. Back of the intermediate distributor
U4 = pressure sensor
X Carefully disconnect the hose from the
pressure sensor (U4).
X Disconnect the connection plugs from their
slots. Refer to the circuit diagram folder for the
relevant machine.
X Remove the intermediate distributor.
X Restore connections X1......X12.
X Push the hose onto the pressure sensor tube
(U4).
X Fasten the intermediate distributor.
NOTE:
X No settings are required.
X The axis machine data can be rewritten in the memory of this board via the SITEST menu
Replace head
.