00195166-0402_SM_D4_EN - 第221页

Settings Calibrating the C&P Head and Cameras C&P12 Service Manual SIPLACE D4 221 6.3 C&P12 6.3.1 Calibrating the C&P Head and Cameras Automatic calibration of all heads and cam eras 6-8: The menu may var…

100%1 / 268
Settings
Gantry Checking the DIP Switches
220 Service Manual SIPLACE D4
6.2.4 Checking the DIP Switches
6.2.4.1 DIP Switch on Gantry Head Distributor
* Not all gantries may be available, depending on the machine type.
6.2.4.2 DIP Switch on Vision Board
* Not all gantries may be available, depending on the machine type.
6.2.5 Mechanical Adjustment of the Incremental Encoder
The incremental encoders (read units) on the X and Y axis are adjusted exactly to the position of the
incremental scale. The two limit marks on the incremental encoder show where the top/bottom positions
of the scale should be. The encoder is also mechanically set to a distance of 0.4 mm +/- 0.1 mm to the
incremental scale.
After this adjustment of the incremental encoder you have to check the zero pulse and track signals.
Correct installation should ensure correct count and zero pulse signals. For troubleshooting purposes
(error analysis and fixing), you will need to measures these signals with the oscilloscope. (See service
manual.)
S Setting for gantry* Comments
1 2 3 4
1 OFF ON OFF ON P0 – gantry ID0 address switch 1 --> gantry
2OFF OFF ON ONP1 – gantry ID1 address switch 2 --> gantry
3 OFF OFF OFF OFF S1 – switch for DLM head (delay switching on
LB down – Z-axis)
4 OFF OFF OFF OFF BL – Enable boot loader for serial port
5 OFF OFF OFF OFF Reset - CAN processor 16 Bit (TQM module)
6 OFF OFF OFF OFF C0 – no current function
7 OFF OFF OFF OFF C1 – no current function
8 OFF OFF OFF OFF S2 – switch for DLM head (no current function)
S Setting for gantry* Comments
1 2 3 4
1 OFF OFF OFF OFF Boot mode - CAN processor 16 Bit via
connector X11
2 OFF OFF OFF OFF Reset - CAN processor 16 Bit to subboard
3 OFF ON OFF ON P0 - Address switch 1 --> Gantry
4OFF OFF ON ONP1 - Gantry address switch 2
5 OFF OFF OFF OFF WPE - Write protect enable, currently OFF
6 OFF OFF OFF OFF CAN R - Switch terminator CAN bus
7ONONONONTest 1 - CAN 1 MBit/s --> ON
8ONONONONTest 0 - CAN IDs --> ON
NOTE:
To set this distance, use one or more small plastic disks with a total thickness of 0.4 mm.
Settings
Calibrating the C&P Head and Cameras C&P12
Service Manual SIPLACE D4
221
6.3 C&P12
6.3.1 Calibrating the C&P Head and Cameras
Automatic calibration of all heads and cameras
6-8: The menu may vary, according to the machine type and configuration.
X In the SITEST menu, select
Calibrate Entire
Machine
-->
All Heads and Cameras
to open
the adjacent menu.
X In
Job Selection
(1) , select the components
to be calibrated.
NOTE:
These two entries (2) are optional.
X To continue calibration with manual handling,
select the four consecutive menus in Section
Positions
(1) and the two menu items in the
Section
Mapping
(2).
Settings
C&P12 Boards at C&P12
222 Service Manual SIPLACE D4
6.3.2 Boards at C&P12
All the settings described in this chapter are head-specific and apply here for the C&P12.
6.3.2.1 8-fold DIP Switch of the gantry head distributor (incl. switch S1) – C&P6/12
Switch P0 and P1:
Switch S1:
ON – Test mode (without delay)
OFF Default state (with delay of 3.6 ms+/- 300 us) means: Z axis moves downwards, the top LB is
released and the LB down is enabled after a delay of 3.6 ms.
See also:
J
Description of LEDs on the Gantry Head Distributor [
J
218]
J
6.2.3.1 Gantry Head Distributor [
J
216]
J
6.3.2.2 LEDs on gantry head distributor [
J
223]
DIP switch Switch position Designation
1 OFF P0 (see below)
2 OFF P1 (see below)
3 OFF "S1" for test mode (see below)
4 OFF BL – Enable boot loader for serial port
5 OFF Res (Reset) – CAN processor 16 bit (TQ module)
6 OFF C0 – no current function
7 OFF C1 – no current function
8 OFF S2 – switch for DLM head (no current function)
S Gantry 1 Gantry 2 Gantry 3 Gantry 4 Designation
1 OFF ON OFF ON P0
2 OFF OFF ON ON G1