00195166-0402_SM_D4_EN - 第245页
Settings Setting the fixed conveyor si de (single and dual co nveyor) Conveyor Service Manual SIPLACE D4 245 6.5.2 Setting the fixed conveyor side (single and dual conveyor) 6.5.2.1 General Notes 6-28: SITEST "Set f…

Settings
Conveyor Adjusting the Tension of the Conveyor Toothed Belt
244 Service Manual SIPLACE D4
6.5.1.1 Measuring Points and Belt Tensions for D4 Conveyor
Legend
Measuring points (arrows) and measuring values
for conveyor belt tensions:
Single conveyor or dual conveyor lane 1
1. Input conveyor: 90 +/- 9 Hz
2. Processing area 1: 72 +/- 7 Hz
3. Intermediate conveyor: 144 +/- 14 Hz
4. Processing area 2: 90 +/- 9 Hz
5. Output conveyor: 90 +/- 9 Hz
Dual conveyor lane 2
1. Input conveyor: 90 +/- 9 Hz
2. Processing area 1: 72 +/- 7 Hz
3. Intermediate conveyor: 115 +/- 12 Hz
4. Processing area 2: 90 +/- 9 Hz
5. Output conveyor: 90 +/- 9 Hz
Width adjustment
Width adjustment Limit switch, 24 +/- 2 Hz

Settings
Setting the fixed conveyor side (single and dual conveyor) Conveyor
Service Manual SIPLACE D4
245
6.5.2 Setting the fixed conveyor side (single and dual conveyor)
6.5.2.1 General Notes
6-28: SITEST "Set fixed conveyor side"
The fixed conveyor side can be set in SITEST if required.
If the position taught for the fixed conveyor side is saved, these values will be used for the function
Move all conveyor edges in standard position
.
The default values will be overwritten and will need to be retaught.
If these dimensions are incorrectly set on the single or dual conveyor, the PCB reference corner may
be moved, leading to fiducial errors during placement.
Two requirements for changing the fixed conveyor sides:
Extra wide conveyor – moves the fixed conveyor side 34 mm outwards.
Widened conveyor – moves the sides of the 2nd conveyor to the limit switch.
Single conveyor control mode (D series up to 380 mm/HF, X lines up to 450 mm)
NOTE:
If you want to change the conveyor mode from "widened" to "extra wide" (or vice versa), you
need to first move the conveyor into standard mode.
NOTE:
This menu is protected with the SIPLACE Service password.
NOTE:
In the SR/MC station SW, the fixed conveyor side of all lanes can be adjusted in the conveyor
firmware (flexible). However, this may only be set with the SITEST software.
NOTE:
In the D series machines, you need to remove the clamping rings on the fixed conveyor side in
advance.

Settings
Conveyor Setting the fixed conveyor side (single and dual conveyor)
246 Service Manual SIPLACE D4
6.5.2.2 Widening the Conveyor (Flexible Dual Conveyor for Single Conveyor Mode)
X In the SITEST conveyor menu
Options and Configurations
select the menu
Change Widening of
Conveyor
to widen the conveyor.
X The conveyor sides of the 2nd conveyor lane (right side fixed (lane 1 left side fixed)) are moved to
the limits.
X The SITEST SW will ask you to connect the lifting tables.
Widening the board conveyor (from its standard width) allows you to use boards up to 380 mm wide.
Widening the board conveyor from the mode "Widened" to the mode "excess width" allows you to place
boards up to a width of 430 mm.
6-29: Setting the "fixed conveyor side" in SIPLACE D series
NOTE:
The fixed conveyor side should be adjusted only with the SITEST software and the width
adjustment devices. This ensures that the conveyor runs straight.