Settings Conveyor Moving the Fixed Conveyor Edge for ’Extr a Wide Conveyor’ 248 Serv ice Manual SIPLACE D4 6.5.3 Moving the Fixed Conveyor E dge for ’Extra Wide Conveyor ’ The standard positions of the fixe d conveyor si…

Settings
Setting the fixed conveyor side (single and dual conveyor) Conveyor
Service Manual SIPLACE D4
247
6.5.2.3 Connecting the Dual Conveyor Lifting Tables
X Remove the lifting table plate on conveyor lane 2 in PA1 and on lane 1 in PA2.
X Loosen the lockscrew(s) (4) and use a screwdriver to push the hexagonal circlip over the shaft on
lifting table 1.
X Perform lifting table connection for all placement areas (arrangement rotated by 180°.)
X Configure the new conveyor mode in SIPLACE Pro
6.5.2.4 Converting the Single Conveyor Mode Back to Flexible Dual Conveyor Mode
X In the SITEST conveyor menu Options and Configurations, select the menu
Change Widening of
Conveyor
to set the default conveyor mode.
X The moveable conveyor side of conveyor 1 (right side fixed (track 1 left side fix)) is moved to a small
conveyor width (default).
X The SITEST SW will ask you to disconnect the lifting tables. Do so.
X The SITEST SW will now use the conveyor control SW to move the fixed side of conveyor 2 (right
side is fixed (lane 1 left side fixed)) back to its standard position. Check the distances between the
two fixed conveyor lanes. (see section (6.5.2.2 Widening the Conveyor (Flexible Dual Conveyor for
Single Conveyor Mode)
J
246 ) )
X Now adjust the conveyor width of both tracks to the required values.
NOTE:
This option is only a mechanical necessity when you use the dual conveyor as a single
conveyor. The two lifting tables move parallel when they are connected.
6-30: Connecting lifting tables (e.g. PA1 conveyor lane 2)
The drive shaft (1) is connected to the piston
rod of the pneumatic cylinder. This shaft is
connected to the shaft of the lifting table for
conveyor lane 1. The lifting table drive shaft
has an additional rod with a hexagon circlip.
This rod is pushed over the shaft of lifting table
1.
Direction of transport (2).
Direction (3) in which the hollow shaft from
lifting table 2 (1 in PA 2) is to be moved to lifting
table 1 (2 in PA 2).
Lock screws (4).
NOTE:
When converting the dual conveyor to a single conveyor (flexible dual conveyor), connect the
lifting tables when requested to do so by SITEST (we recommend doing this without the
compressed air supply to the lifting table).
This function is supported by SIPLACE Pro .

Settings
Conveyor Moving the Fixed Conveyor Edge for ’Extra Wide Conveyor’
248 Service Manual SIPLACE D4
6.5.3 Moving the Fixed Conveyor Edge for ’Extra Wide Conveyor’
The standard positions of the fixed conveyor sides are preset.
X In the SITEST conveyor menu
Options and Configurations
and select the menu
Conveyor
Excess Width,
to set the conveyor mode "Extra wide".
X The fixed conveyor side of conveyor 2 (right side fixed (track 1 left side fix)) remains in its position.
X The ’fixed conveyor of track 1(right side fixed (track 2 left side fix)) is moved 34mm to the outside.
This allows you to use wider boards. The flexible conveyor side on lane 2 (lane 1 left fixed) can now
be set to accommodate boards which are wider than 216 mm (242 mm).
NOTE:
This operating mode is possible for D machines with single or dual conveyors.
ATTENTION:
After the conversion process, you need to measure/calibrate the board reference corner and the
conveyor sides and then save this information in the machine data.

Settings
Checking the Limit Switch Position Conveyor
Service Manual SIPLACE D4
249
6.5.4 Checking the Limit Switch Position
X Check the minimum and maximum width and ensure that the conveyor sides are parallel.
6-31: Position of the width adjustment and conv. side limit switches (symbolic
draw)
Legend
1. Limit switch on the input conveyor - fitted
below the conveyor side edge
2. Limit switch on the input conveyor - fitted
below the conveyor side edge
3. Limit switch for the width adjustment unit
4. Transport direction
Limit switch on the input conveyor:
There are 5 limit switches below the conveyor
side edges near the input conveyor. The limit
switch is designed to prevent the conveyor
sides hitting one another or the conveyor
frame.
Limit switch on the output conveyor:
In the vicinity of the output conveyors, there
are 2 limit switches for the adjustment unit.
They serve to protect the traveling range and
initialize (right side) the adjustment unit for the
width adjustment.
Setting Value
Minimum width: 49.7 mm
Maximum width of single conveyor 508.5 mm
Maximum width of dual conveyor 216.5 mm (standard)
Maximum width of dual conveyor 242.5 mm (Standard)