00195166-0402_SM_D4_EN - 第30页
Overview Electrical System Distributors in Sectors 1-4 30 Serv ice Manual SIPLACE D4 3.2.3.5 Overview of Settings Description Setting Settings Vision DC/DC converter replaced No settings required CAN Bus board - CO table…

Overview
Distributors in Sectors 1-4 Electrical System
Service Manual SIPLACE D4
29
3.2.3.4 Distributors in Sector 4
3-13: Overview - distributors in sector 4
Legend
1 Fine fuse 5x20 MT 3.15 A [00302999-xx] 5 CAN I/O module 2 [00355051-xx]
2 Resistor R1 6 DIP switch for CAN Bus terminator for CO table
in Sector 4
3 CAN interface [03032364-xx]
4 CAN bus terminator board for changeover table
[03046863-xx]
7 DIP switch for configuration of CAN I/O module
in sector 4

Overview
Electrical System Distributors in Sectors 1-4
30 Service Manual SIPLACE D4
3.2.3.5 Overview of Settings
Description Setting Settings
Vision DC/DC converter replaced No settings required
CAN Bus board - CO table terminator replaced Configuration of DIP switch
See
section (3.2.3
Distributors in Sec-
tors 1-4
J
26 )
Fine fuse 5x20 MT 3.15 A replaced No settings required
Relay RS30 24 V replaced No settings required
CAN interface replaced Configuration of DIP switch
See
section (3.2.3
Distributors in Sec-
tors 1-4
J
26 )
CAN I/O module 2 replaced Configuration of DIP switch
See
section (3.2.3
Distributors in Sec-
tors 1-4
J
26 )
Resistor R1 replaced No settings required

Overview
Computer Unit Electrical System
Service Manual SIPLACE D4
31
3.2.4 Computer Unit
3-14: Computer unit
Legend
3.2.4.1 Overview of Settings
1 Control computer [0302341-xx] 4 Video multicoupler [03040316-xx]
2 Machine controller [03047697-01] 5 USB hub 2.0 [03032344-01]
3 Hotlink interface [03032343-xx]
Description Setting Comments
Control computer replaced No settings required Backup of machine data
Install software according to respective
installation guide.
Video multiplexer replaced No settings required
Hotlink interface replaced No settings required Make sure that card engages correctly in
the slot.
USB hub 2.0 replaced No settings required
Machine controller replaced No settings required