Service Work Gantry Rep lacing the X Motor Unit [00333167 -03] 74 Serv ice Manual SIPLACE D4 4.2.8 Replacing the X Motor Unit [00333167-03] Tools and Equipment  Set of DIN 911 Allen keys  Cable ties  Belt tension meas…

100%1 / 268
Service Work
Replacing the X Axis Toothed Belt [00331076-02] Gantry
Service Manual SIPLACE D4
73
4.2.7.5 Settings
See also:
J
4.2.7.4 Installing the X-axis toothed belt [
J
72]
4-21: Fixing the X-axis toothed belt to the tension jack
X Push the head mount (1) towards the X axis
motor unit, as far as the stop on the
elastomeric spring.
X Turn the hexagon socket-head screw (5) to set
the belt tension to 53 Hz 1/3 Hz.
CAUTION:
Do not overstretch the toothed belt
when adjusting the belt tension.
X Secure the hexagon socket-head screw (5)
with the locknut.
Service Work
Gantry Replacing the X Motor Unit [00333167-03]
74 Service Manual SIPLACE D4
4.2.8 Replacing the X Motor Unit [00333167-03]
Tools and Equipment
Set of DIN 911 Allen keys
Cable ties
Belt tension measuring device TSM [00326015-01]
"Measuring belt tensions" operating instructions
Parts
X motor unit [00333167-03]
Removing the X-axis motor unit
4-22: Replacing the X-axis motor unit
Legend
X Switch off the machine and secure it to prevent unauthorized reactivation.
1 Head mount 7 2 x M6x14 hexagon socket-head screws
2 M4 x35 hexagon socket-head screw for
tensioning the X toothed belt
8Locknut
3 Synchroflex X-axis toothed belt 9 Board holder
4 X-axis motor unit 10 Cable clamps
5 X/Y distributor 11 Cable clamp
6 X5 socket for X-axis motor
Service Work
Replacing the X Motor Unit [00333167-03] Gantry
Service Manual SIPLACE D4
75
Gantry 1 or 3
X Remove the black cover strip on the cross-beam above the gantry concerned:
Unplug the fan cable. The fan is fixed to the black cover strip.
Remove the black cover strip (3 M6x8 hexagon socket-head screws).
X Cut the cable ties holding the X-axis motor cable.
X Remove the cable clamp for the flat ribbon cable (11).
X Disconnect all the plugs from the X/Y distributor (5).
X Remove the X/Y distributor (5).
X Remove the board holder for the X/Y distributor (9).
X Remove the cable holders (10) on the trailing cable.
X To relax the toothed belt (3), proceed as follows:
Loosen the locknut (8),
Turn the hexagon socket-head screw (2) counterclockwise.
X Loosen the two M6 x14 hexagon socket-head screws (7) fixing the X motor unit (4).
X Pull the X motor unit (4) up and out,
X at the same time pushing the board holder slightly to the side.
Gantry 2 or 4
X Remove the black cover strip on the cross-beam above the gantry concerned:
Unplug the fan cable. The fan is fixed to the black cover strip.
Remove the black cover strip (3 M6x8 hexagon socket-head screws).
X Cut the cable ties holding the X-axis motor cable.
X Remove the cable clamp for the flat ribbon cable (11).
X Disconnect all the X motor plugs from the X/Y distributor (5).
X Remove the board holder for the X/Y distributor (9).
X Remove the cable holders (10) on the trailing cable.
X To relax the toothed belt (9), proceed as follows:
Loosen the locknut (8),
Turn the hexagon socket-head screw (2) counterclockwise.
X Loosen the two M6 x14 hexagon socket-head screws (7) fixing the X motor unit (4).
X Pull the X motor unit (4)
up and out,
at the same time pushing the board holder slightly to the side.
DANGER: POWERFUL MAGNETIC FIELD
X Always follow the special safety instructions when working in the vicinity of powerful magnetic
fields.