00196428-0102_AI_Reconfig_Kit_X-Serie_CPP_DE EN - 第102页

2 Assembly Instructions Head Reconfiguration Kit CPP for the SIPLACE X Series Head Reconfiguration Kit 2.7 Installing the CPP Placement Head Issue 03/2010 102 X Push the placement head ou twards for the measurement. X Pl…

100%1 / 128
Head Reconfiguration Kit 2 Assembly Instructions Head Reconfiguration Kit CPP for the SIPLACE X Series
Issue 03/2010 2.7 Installing the CPP Placement Head
101
2.7.6 Installing and Setting the Height of the Nozzle Station
CAUTION:
Depending on the installation location (one-gantry placement area) the component trol-
ley docking unit must be released and pushed outwards. To do this, it is absolutely nec-
essary to read the relevant Service Manual. When the work is completed, the
component trolley docking unit must be refitted and all add-on parts (nozzle changer) re-
calibrated. 2
CAUTION:
Different nozzle stations are used for the X and the X4I series: 2
Nozzle station CPx cplt. X Series [03073328-xx]
Nozzle station CPP cplt. X4I [03074861-xx]
CAUTION:
The nozzle station only works with the new CAN node. From component trolley docking
unit [03015680-07] onwards, the CAN node is already included. Otherwise, it can be up-
graded by the Service. 2
2 Assembly Instructions Head Reconfiguration Kit CPP for the SIPLACE X Series Head Reconfiguration Kit
2.7 Installing the CPP Placement Head Issue 03/2010
102
X Push the placement head outwards for the measurement.
X Place the caliper on the top edge of the nozzle reject device and measure the distance to the
top edge of the bottom linear guide rail of the X axis.
2
2
X Set the distance to 139.0 ±0.2 mm for all placement heads.
When the distance is correct, continue with installing the nozzle changer into the placement
machine.
CAUTION:
Hold the caliper vertically! 2
Rest the bottom edge of the cali-
per on the reject device .
Rest the top edge of the caliper on
the linear guide rail.
Head Reconfiguration Kit 2 Assembly Instructions Head Reconfiguration Kit CPP for the SIPLACE X Series
Issue 03/2010 2.7 Installing the CPP Placement Head
103
X If the distance is too large, insert shim plates:
Shim plate for nozzle reject device [03039514-xx and 03021079-xx],
screws DIN7991 M4x20 - 8.8 [00333782-xx].
2
X Remove the cover plate above the component reject bin.
Slot
Shim plates