00194591_02.pdf - 第40页
3 Instal lation Installation Manual SIPLACE Setup Center RF 2.1 3.3 Installation of SIPLACE Setup Center and Possible Setup Types Edition 09/2005 EN 40 3.3.3.6 Setting up the Scanner Setting up the scanner system re quir…

Installation Manual SIPLACE Setup Center RF 2.1 3 Installation
Edition 09/2005 EN 3.3 Installation of SIPLACE Setup Center and Possible Setup Types
39
3.3.3.4 Scanner Hardware Installation
The Dragon scanner's cradle needs to be connected to the PC's COM-port. The default port is
COM1. 3
If the COM1 port is already in use another COM port need to be configured (Another port can be
configured in the Setup Center: 3
→ Open Setup Center setting dialog - menu Options/Settings - dialog Scanner/Dragon Scanner/
Serial Port).
→ Connect the cradle to the Setup Center PC according to the following picture:
3
Fig. 3.3 - 27 RS232 Connection
3.3.3.5 Safety Instructions
The Dragon Scanner conforms to laser class 2. 3
LASER RADIATION!
Do not look into beam
Laser class 2 3
Warning label W216 (shown above) is displayed on the Dragon scanner. 3
CAUTION
Before using the Dragon scanner, inform all operating personnel about the laser regulations.
While operating the Dragon scanner, observe the respective regulations in line with VDE 0837
„Protection from radiation emitted by laser devices“ and the „Laser radiation“ accident prevention
regulations (VBG93), applicable in Germany.
Also observe the accident prevention regulations applicable in your country.
Despite the low laser power, avoid looking directly at the laser beam. The natural closure reflex of
your eyelids will protect your eyes from the visible beam. 3

3 Installation Installation Manual SIPLACE Setup Center RF 2.1
3.3 Installation of SIPLACE Setup Center and Possible Setup Types Edition 09/2005 EN
40
3.3.3.6 Setting up the Scanner
Setting up the scanner system requires three steps: 3
(1) Scanner configuration
(2) Binding the scanner to the RF station
(3) RF station configuration
3.3.3.7 Scanner Configuration
The new Scanner is setup up by scanning of a series of barcodes. Pull the trigger to switch the
scanner on and scan the following barcodes in the order they are printed. 3
Note
The configuration must be completed in one run. If it is halted or any problems appear, all config-
uration steps have to be redone from the start. 3
3
3
3
3
3
Set DLL6000-R compatibility
Restore DRAGON ™ M standard configuration
Restore DRAGON ™ M default
Enter Configuration

Installation Manual SIPLACE Setup Center RF 2.1 3 Installation
Edition 09/2005 EN 3.3 Installation of SIPLACE Setup Center and Possible Setup Types
41
3
3
3
3
3
3
3
Radio protocol timeout
1
9
Two-Ways
Display-off Timeout
9
0