00196962-04-BA-SX12-V2-EN - 第44页
2 Operational safety User manual SIPLACE SX1/SX2 2.2 Warning labels From software version SC 706.1 SP1 Version 10/2014 44 2.2.3.1 W arning label 202 2 W202, in fig. 2.2 - 3 , page 43 , item no. 03009341-01 (quantity per …

User manual SIPLACE SX1/SX2 2 Operational safety
From software version SC 706.1 SP1 Version 10/2014 2.2 Warning labels
43
2.2.3 Warning labels on the gantries
Fig. 2.2 - 3 Warning label W202 on the gantries
2
W202, item no. 03009341-01
W202, item no. 03009341-01
W 202
W 202
W 202

2 Operational safety User manual SIPLACE SX1/SX2
2.2 Warning labels From software version SC 706.1 SP1 Version 10/2014
44
2.2.3.1 Warning label 202
2
W202, in fig. 2.2 - 3, page 43, item no. 03009341-01
(quantity per SX1 machine: 2, SX2 machine: 2)
W202, in fig. 2.2 - 3
, page 43, item no. 03009341-01
(quantity per SX1 machine: 1, SX2 machine: 2)
2
2
CAUTION
Data loss due to powerful magnetic fields!
There is a risk that the powerful magnetic fields could corrupt data on data media or credit
cards and check cards.
Keep data carriers and check cards away from the machine.
DANGER
Danger to life from powerful magnetic fields inside the machine!
When protective covers are opened inside the machine, the life of persons with the follow-
ing passive or active implants is put at risk:
– Pacemakers
– Defibrillators
– Insulin pumps etc.
At-risk people must not stand in the immediate vicinity of the machine.

User manual SIPLACE SX1/SX2 2 Operational safety
From software version SC 706.1 SP1 Version 10/2014 2.2 Warning labels
45
2
2.2.4 Warning label W205 on the tape cutter
2
Fig. 2.2 - 4 Warning label W205 on the top of the tape cutter
W205, item no. 03009344-01
WARNING
DANGER OF CRUSHING!
There is a danger of crushing for persons with passive metal implants (e.g. plates,
screws).
Never reach into the machine when the protective covers are open and do not bend
over the open machine.
Do not bring any metal objects into the danger area.
W205