00196962-04-BA-SX12-V2-EN - 第96页

3 Technical data and assemblies User manual SIPLACE SX1/SX2 3.1 Performance data for SIPLACE SX1/SX2 From software version SC 706.1 SP1 Version 10/2014 96 3.1.4 Component feeding 3 3 Feeder locations Component trolley wi…

100%1 / 370
User manual SIPLACE SX1/SX2 3 Technical data and assemblies
From software version SC 706.1 SP1 Version 10/2014 3.1 Performance data for SIPLACE SX1/SX2
95
3.1.3 PCB conveyor - data
3
Single conveyor Flexible dual conveyor Dual conveyor in single con-
veyor mode
Standard dimensions
(length x width)
50 mm x 50 mm to
450 mm x 560 mm
*a
50 mm x 50 mm to
450 mm x 260 mm
50 mm x 50 mm to
450 mm x 460 mm
Dimensions with “Long
Board”option
(length x width)
50 mm x 50 mm to
850 mm x 560 mm
50 mm x 50 mm to
850 mm x 260 mm
50 mm x 50 mm to
850 mm x 460 mm
Stationary conveyor side Right, left or outer
Automatic electrical
width adjustment
Standard
PCB thickness
Standard:
"Thick board" option
0.3 mm to 4.5 mm
2.0 mm to 6.5 mm
Clamping length of board 450 mm
Space for positioning
support pins
440 mm
PCB warpage See page 135
PCB weight
*b
Standard max. 2.0 kg max. 1.0 kg max. 2.0 kg
Clearance on PCB under-
side
*c
25 mm
PCB conveyor height
Option:
Standard:
SMEMA option:
900 mm
930 mm
950 mm
Type of interface:
Standard:
Option:
SMEMA
Siemens
Component-free PCB
handling edge
3.0 mm
PCB changeover time
Single conveyor
Dual conveyor
*d
< 1.5 seconds
0 seconds
*)a When using board widths > 450 mm, make sure that the peripheral modules can also process these board
widths.
*)b The board weight value refers to the weight of the board plus the weight of the components.
*)c The free positioning of support pins is limited by the stop bar.
*)d 0 seconds in asynchronous mode, otherwise 1.5 seconds.
Important notes
When setting up a machine (S; F-, HS-, HF-, X- or D-Series) next to a SIPLACE SX, be aware that there is limited room between the two
machines. In these cases, use suitable conveyor extensions to create room of 0.5m for the operator between the two machines.
3 Technical data and assemblies User manual SIPLACE SX1/SX2
3.1 Performance data for SIPLACE SX1/SX2 From software version SC 706.1 SP1 Version 10/2014
96
3.1.4 Component feeding
3
3
Feeder locations
Component trolley with 60 tracks
Component trolley with 30 tracks
60 feeders with 8 mm
30 feeders with 8 mm
Component trolley changeover time < 1 minute
Max. component feeding
(2 component trolleys on the SIPLACE SX)
2 component trolleys with tape reel holder and
integral waste tape bins:
When using a waffle pack changer:
120 locations for feeders with 8 mm.
90 locations for feeders with 8 mm.
Feeder module types (SIPLACE X) Tape feeder modules, tray feeders (with X reject - conveyor
adapter),
linear vibratory feeders and label feeders.
feeding capacity
(2 component trolleys on the SIPLACE SX)
120 tape feeder modules 4 mm X
120 tape feeder modules 8 mm X
60 tape feeder modules Smart Feeder 2x8 mm X
60 tape feeder modules, Smart Feeder 12 mm X
60 tape feeder modules, Smart Feeder 16 mm X
40 tape feeder modules 24 mm X
30 tape feeder modules 32 mm X
24 tape feeder modules 44 mm X
20 tape feeder modules 56 mm X
16 tape feeder modules 72 mm X
12 tape feeder modules 88 mm X
User manual SIPLACE SX1/SX2 3 Technical data and assemblies
From software version SC 706.1 SP1 Version 10/2014 3.2 Ambient conditions and connection values
97
3.2 Ambient conditions and connection values
3.2.1 Ambient conditions for packaging, transportation and storage
3
3.2.2 Ambient conditions for machine operation
3
3.2.3 Electrical ratings
3
Temperature range Between -25°C and 55°C
Atmospheric humidity Up to 95%
Ambient pressure Up to 3000 m height without pressure equalization
Room temperature Between 15°C and 35°C
Atmospheric humidity 30% to 75 % (no higher than 45% on average to prevent any
possibility of condensation on the machine)
Ambient pressure > 750 mbar (corresponds to 2500 m above mean sea level)
Electrical ratings
Supply voltage Fuse
Main power supply 3 x 200 V~ ± 10 %; 50 Hz (North
Japan)
*a
3 x 220 V~ ± 10 %; 60 Hz (South Japan)
3 x 208 V~ ± 10 %; 50/60 Hz (U.S.A)
a
3 x 230 V~ ± 10 %; 50/60 Hz
3 x 380 V~ ± 10 %; 50/60 Hz
3 x 400 V~ ± 10 %; 50/60 Hz (Europe)
3 x 415 V~ ± 10 %; 50/60 Hz
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 16 A characteristic C
3 x 16 A characteristic C
3 x 16 A characteristic C
Mains power connection Cable 5 x 4 mm² with CEKON connector 5 x 32 A (3 x 200 V~ / 208 V~ / 220 V~/ 230 V ~)
Cable 5 x 4 mm² with CEKON connector 5 x 16 A (3 x 380 V~ / 400 V~ / 415 V~)
Energy consumption
Energy consumption
without vacuum pump
Energy consumption
with vacuum pump
*b
Nominal apparent
power
SIPLACE SX1
SIPLACE SX2
1.8 kVA
2.4 kVA
3.0 kVA
3.6 kVA
Nominal active power
SIPLACE SX1
SIPLACE SX2
1.2 kW
1.6 kW
2.0 kW
2.4 kW
*)a Connection at terminals 3 x 204 VAC on transformer T1