00198545-01_JCPM_WF2_CA4V2_EN - 第21页

4 WF2 CA4 V2 Remove the C&P20 M2 head 12 min 1 / 2 C A U T I O N !  R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e Machine Status OFF …

100%1 / 50
www.asm-smt.com
4 WF2 CA4 V2 Remove the C&P20 M2 head 12 min 1 / 2
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T7, T8, T9, T15, T19, T49, T62
Wear Part: Consumables:
www.asm-smt.com
1 Move all gantries to a good working posi-
tion.
2 Fit the component sensor protection on
the head.
3 Unplug the 3 compressed air connections.
4 Open the cover and disconnect both rib-
bon cables.
5 Open the strain relief. 6 Unplug the camera cables.
4 WF2 CA4 V2 Remove the C&P20 M2 head 12 min 2 / 2
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T7, T8, T9, T15, T19, T49, T62
Wear Part: Consumables:
www.asm-smt.com
7 Loosen the 4 fixing screws. 8 Take the head from the hook. 9 Put the head into the transport container.
10 Remove the vacuum elbow. 11 Head ready for maintenance.