00198545-01_JCPM_WF2_CA4V2_EN - 第29页
8 WF2 CA4 V2 Clean the conveyors, lifting tables and gantry cables 5 min 1 / 1 C A U T I O N ! R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n…

7 WF2 CA4 V2 Check and clean the magnetic surface and scale of the X- and Y-
Axis
5 min 2 / 2
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T3
Wear Part: Consumables:
C3, C5
www.asm-smt.com
7 If you see any damage contact Service. 8 If OK -> clean the Y-Axis magnets at
gantry 1/3 (2/4).
9 Clean the Y-Axis scale at gantry 1/3 (2/4).
10 Move all gantries to the end limit at loca-
tion 1/3.
11 Repeat steps 2 to 7 for gantry 2/4.

8 WF2 CA4 V2 Clean the conveyors, lifting tables and gantry cables 5 min 1 / 1
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T1
Wear Part: Consumables:
C3
www.asm-smt.com
1 Clean all X-Axis gantry cables at gantry
1/3.
2 Clean all Y-Axis gantry cables at gantry
1/3.
3 Move all gantries to the end limit at loca-
tion 2/4 and repeat steps 1 to 2 for gantry
2/4.
4 Vacuum all loose components on and
around the whole PCB conveyor.

www.asm-smt.com