00197396-02_AI_Serviceflap_X-Series_S_DE_EN - 第47页

3 Installation 3.6 Fitting the Service Flap Assembly Instructions / Montageanleitung SIPLACE X-Series S Service Flap Serviceklappe 07/2019 47 3.6 Fitting the Service Flap Fig.14: Fitting the service flap ► Align the ser…

100%1 / 50
3 Installation
3.5 Fitting the Security Switch
46 Assembly Instructions / Montageanleitung SIPLACE X-Series S Service Flap Serviceklappe 07/2019
3.5 Fitting the Security Switch
Fig.11: Fasten the ball holder
The safety switch is prefitted to the support
plate. The ball holder still needs to be fitted,
preferably before you install the safety
switch in the machine.
Fasten the ball holder down on the
safety switch at the points marked (1)
and (2).
Fig.12: Support plate with safety switch fastened to it
Use four nuts and washers to fasten
the support plate with the safety switch
to the inside of the cover (1)
. The point marked (2) shows the ball
holder when fitted.
Fig.13: Cables
Unplug the line from the existing safety
switch at the press-fit connection under
the center cover and integrate the
safety switch into the safety loop (1).
Run the cable for the new safety switch
parallel to the existing one(2).
3 Installation
3.6 Fitting the Service Flap
Assembly Instructions / Montageanleitung SIPLACE X-Series S Service Flap Serviceklappe 07/2019 47
3.6 Fitting the Service Flap
Fig.14: Fitting the service flap
Align the service flap centrally to the slots in the slider.
Use a washer and nut to fasten the service flap to the slider (2). Do not tighten the nuts yet.
Fasten the EMC tape for the hinge to the top of the door (1).
Now tighten the screws for the hinges at the top and bottom. Make sure that you have equal
gaps between the top cover and the machine base (3).
Adjust the safety switch and the actuating bracket so that the door can be easily closed (ad-
justing plates).
3.7 Final Work:
Switch the machine back on and boot the station computer.
Perform a function test for the new security switch.
Check the emergency stop loop and the signaling loop.
3 Installation
3.7 Final Work:
48 Assembly Instructions / Montageanleitung SIPLACE X-Series S Service Flap Serviceklappe 07/2019