- 22 - 4.7.5. Placeme nt enable range on the top and bottom surfaces of PWB *1 : Maximum height s of components that can be placed Ma xi mu m Component size S pecification of componen t height Component diagonal less tha…

- 21 -
* For the L-Wide PWB specification, any pin reference option cannot be selected.
PWB transport direction
Placement disable range
61mm
20mm
22.6mm
0 to 292 mm Moving part
4.5mm
Placement disable range
PWB transport direction
Placement disable range
24.5mm
24.5mm
23mm
L-Wide PWB specification
XL Wide PWB specification
26mm
39.3mm
26.5mm
13mm
26mm
26.5mm
20mm
23mm
22.6mm
0 to 280.6 mm Moving part
6.5mm
Placement disable range
18.5mm
28mm

- 22 -
4.7.5. Placement enable range on the top and bottom surfaces of PWB
*1:Maximum heights of components that can be placed
Maximum
Component size
Specification
of component height
Component
diagonal less than
50 mm
Component
diagonal 50 mm or
more to less
than 88 mm
Component
diagonal 88 mm or
more
SC specification 6mm
- -
NC specification 12mm 12mm 5mm
HC specification 20mm 20mm 5mm
EC specification 25mm 20mm 5mm
PWBs clamping method
This is a method to use the PWB top surface as a reference to have both the PWB front and
rear ends each at the fixed and movable sides supported to the transport rails, then, to clamp
the PWBs.
PWB width adjusting methods
* Standard: Manually adjusting method with your hand
* Option: Automatic PWB width adjusting method via a motor
(Minimum board size: 50.0 mm x 50.0 mm)
PWB positioning reference
* Shape reference
* Pine reference (optional)
Maximum *1
SC: 6mm
NC: 12mm
HC: 20mm
EC: 25mm
3mm
3mm
MAX. 40 mm

- 23 -
4.7.6. Function correcting the PWB positions
Field of vision for recognizing the PWB reference marks
□6. 3 mm (camera’s field of vision for recognition).
Figure Field of vision for recognizing the PWB reference marks
Window size for recognizing the PWB reference marks
This size can be changed within a maximum of 6.3 mm, subject to securing a clearance
between the recognition mark and its surrounding area.
Kinds of recognition marks and corrective method
- PWB reference mark
Two or three marks are located on a PWB to correct the entire PWB.
When a machine detects two PWB reference marks, it corrects the positioning, angle and
expansion/contraction of the entire PWB. When detecting three PWB reference marks,
it corrects the perpendicularity in the X and Y direction also.
- Component positioning marks
If a component such as an IC (QFP) needs to be placed on a board very precisely, two or
three marks set on a component itself are used to correct each component placement
position.
- Marks used to position the component area
Two marks (their positions can be set as you like) are to be provided to a group of
components placement positions, and they are used to correct each component
placement position in the group.
Note
:
The position is arbitrary, subject to not aligning three (3) reference makes,
if this is the case, on one (1) straight line. (It is recommended that the reference marks should
be made at the four (4) corners of the PWBs.
Field of vision for PWBs recognition
Recognition mark
PWB
6.3mm