00191297-02 - 第136页

4 Placement Functions User Manual SIPLACE S-23 HM 4.3 Feeders Software Version SR.405.xx 05/99 Issue 134 4.3.2 "Omit Component s" V iew With the h elp of t he "Omi t componen ts" functio n in this vie…

100%1 / 422
User Manual SIPLACE S-23 HM 4 Placement Functions
Software Version SR.405.xx 05/99 Issue 4.3 Feeders
133
4.3.1.3 "Refilling" Empty Tracks
È Select the entry in the table or the track that is to be confirmed as being "refilled". The line se-
lected is highlighted in light blue in the table and the "Selected track" button is active.
È Click on the Selected track button when the feeder in this track has been refilled with compo-
nents.
The track is then considered full and the entry is deleted from the list of empty tracks.
The "Selected track" button is not active thereafter.
4.3.1.4 Refilling All Empty Tracks of a Location
È Click on the button for the location that is to be confirmed as being "refilled", e.g. Location 1.
All tracks of this location are then considered refilled and the corresponding entries for the
empty tracks in this location are deleted from the list of empty tracks.
The button for the location is not active thereafter.
4.3.1.5 Refilling Empty Track When the "Component Verification With Barcode" Option
is Active
When the "Component verification with barcode" option is active, then empty tracks can normally
only be confirmed as having been "refilled" in the manner described in Section 4.3.1.5.
The tracks containing components without
component barcodes are an exception. You can man-
ually "refill" here even if the "Component verification with barcode" option is active. 4
È Select the entry in the table (see Fig. 4.3 - 2) for an empty track that contains components with-
out barcodes (see the note on page 4 - 132).
The "Selected track" button is active.
È Click on the Selected track button when the feeder in this track has been refilled.
The "Selected track" button is not active thereafter.
4 Placement Functions User Manual SIPLACE S-23 HM
4.3 Feeders Software Version SR.405.xx 05/99 Issue
134
4.3.2 "Omit Components" View
With the help of the "Omit components" function in this view, you can omit specific components
from selected tracks when inserting components in the current PCB.
This is necessary, for example, when components have not been correctly inserted in the first PCB
of a new cluster. The components placed under "Omit components" are then ignored in all tracks
containing these components when inserting components into the current PCB. The incompletely
populated PCBs are then transported in the output conveyor and must be removed by hand.
After the PCB has been removed, the "Omit components" setting is reset for the components not
inserted, and they will then be used to populate the next PCB. 4
4
È Click on the icon.
The "Omit components" view is displayed (see Fig. 4.3 - 3).
4
Fig. 4.3 - 3 "Omit components" view
NOTE
The "Omit components" function cannot be executed in the "Operator" access level. 4
User Manual SIPLACE S-23 HM 4 Placement Functions
Software Version SR.405.xx 05/99 Issue 4.3 Feeders
135
4.3.2.1 Meaning of the Entries in the Tables of the "Omit Components" View
Loc.
Number of the location
Tr D T
Number of the track and of the feeder division
The entry for "T" is irrelevant for model SIPLACE S-23 HM machines.
(Only valid for automatic machines with wafflepack changers)
CmpName
Name of the component
GF no.
Number of the package form
4
4.3.2.2 Omit Component
È Select the entry for the component that is to be omitted in the "Empty tracks" table. The line
selected is highlighted in light blue in the table.
The "Omit components" button is active.
È Click on the Omit components button. The following selection box is opened.
4
È Confirm the query with Yes.
The entries for all tracks whose feeders contain the components that are not to be used to pop-
ulate the current PCB are displayed in the "Omitted components with alternate tracks:" table.
4