User Manual SIPLAC E S-23 HM 5 Single Functions Software Version S R.405.xx 05/99 Issue 5.2 Single functions, Gantry 155 5.2.6.1 General comments In the "Noz zle cha nger conf iguratio n revol ver head " screen…

100%1 / 422
5 Single Functions User Manual SIPLACE S-23 HM
5.2 Single functions, Gantry Software Version SR.405.xx 05/99 Issue
154
5.2.6 "Nozzle changer configuration revolver head" screen
5
È In the current screen for the single function for Gantry x, click the symbol .
NOTE
The nozzle changer must be installed and configured in the machine options. When calling
this menu the nozzles on the placement head are returned to the nozzle changer. 5
The user interface is switched to the "Nozzle changer configuration revolver head" screen (see
Fig. 5.2 - 6). 5
5
Fig. 5.2 - 6 "Nozzle changer configuration revolver head" screen
User Manual SIPLACE S-23 HM 5 Single Functions
Software Version SR.405.xx 05/99 Issue 5.2 Single functions, Gantry
155
5.2.6.1 General comments
In the "Nozzle changer configuration revolver head" screen there are functions which allow you to
adjust and confirm the nozzle configuration for the individual magazines in the nozzle changer.
Click on the appropriate button to carry out the required function.
The nozzle changer configuration is displayed in the table in the display.
5
Conditions for changing the set-up of the nozzle changer
Remember the following points when changing the set-up: 5
The magazines may only be filled when all nozzles on the revolver head have been returned
to their magazines.
Magazines may only contain nozzles of one type.
The maximum number of nozzles per magazine is 12.
The maximum number of magazines on a nozzle changer is 7.
The magazines must be filled outside the machine and must only ever be changed in their en-
tirety.
To remove and load nozzles you must open the lock. Once you have finished, you must then
close the lock again.
Meaning of the entries in the table in the display
Magazine
Number of the magazine
Number
Number of nozzles in the magazine
Actual
Type of nozzles currently in the magazine
Preset
If the type of nozzle currently in the magazine is not the same as shown in this column, then it
is to be changed
To change
An arrow ( <== ) in this column indicates that the nozzle type currently in the magazine ("Ac-
tual" column) must be changed for the nozzle type shown in the "Preset" column.
5 Single Functions User Manual SIPLACE S-23 HM
5.2 Single functions, Gantry Software Version SR.405.xx 05/99 Issue
156
5.2.6.2 Functions
Lock. op./close 5
To be able to fill the magazine manually, you must use this function to open the lock (locking
plate) on the nozzle changer and close it afterwards.
È Click the Lock. op./close button.
The magazine locking plate is opened.
È Click the Lock. op./close button.
The magazine locking plate is closed again.
Refill 5
This function allows you to refill the magazine with new nozzles of the type already in use (or in
other words, the set-up itself is not changed).
During placement operation it may be necessary to refill individual magazines with nozzles. You
must fill the magazine with 12 nozzles and these must be of the same type that were originally
contained in the magazine. 5
The nozzle types shown in the columns "Actual" and "Preset" of the table will agree.
The number of nozzles in the magazine is shown in the "Number" column. 5
È Select the entry corresponding to the magazine you want to fill with nozzles. This line is then
highlighted in light blue.
È Click the Lock. op./close button.
È Fill the magazine with the same type of nozzle it originally contained.
NOTE
The magazines must always be completely refilled (12 nozzles of the same type for each
magazine). 5
È Click the Lock. op./close button again.
È Click the Refill button.
The entry in the "Number" column is updated and now shows the new number of nozzles in