User Manual S-23 HM 6 Vision functions
Software Version SR.405.xx 05/99 Issue 6.6 Test Component
275
6.6.4.16 ‘Size’ measuring mode
Click on the ‘Setting’ field for the ‘Size’ measuring mode to overlay the Size measuring mode
menu on the screen. 6
6
Fig. 6.6 - 35 Measuring mode option, Size measuring mode menu
This menu is used to 6
vary the resolution the angle calculation.
specify the method for the rotation calculation and
vary the integration settings.
Resolution for the angle calculation 6
In this measuring mode, if the component rotation has been calculated incorrectly on account of
ambiguity, you can increase the angular resolution in order to determine the angle of rotation. The
following increments may be used in relation to the resolution in order to determine the angle of
the components: 6
Simple components: Low resolution:
Complex components: High resolution
6 Vision functions User Manual S-23 HM
6.6 Test Component Software Version SR.405.xx 05/99 Issue
276
Method for calculating the rotation 6
Here you must specify the number of rotation windows in order to determine the angle: 6
Automatic selection
The system selects the number of windows.
SWIN method (Single Window)
Selects a single window. This method is suitable for small and complex components or com-
ponents with fluctuating dimensions.
TWIN method (Two Windows)
Two windows are selected. This method is particularly suitable for rapid analysis, for PLCCs,
for example. However, this requires the structures to be investigated to lie in the center of the
window. If this is not the case, select just one window (SWIN method).
Integration settings 6
If you click on the 'Integration settings' field, the Integration settings of Size measuring mode
menu will appear on screen. 6
6
Fig. 6.6 - 36 Measuring mode option, Integration settings of Size measuring mode menu
User Manual S-23 HM 6 Vision functions
Software Version SR.405.xx 05/99 Issue 6.6 Test Component
277
This menu is used to select the 6
integration direction,
the resolution in the measuring direction and
the resolution in the integration direction.
Integration direction 6
In order to determine the angle, select the integration direction towards either the X or Y axis of
the component. We recommend that you select the longer edge. 6
Resolution in the measuring direction 6
Select this resolution in order to optimize the measuring times at the revolver head. 6
Resolution in the integration direction 6
Select this resolution in order to optimize the measuring times at the revolver head. 6
Resolution
in the measuring direction
Resolution
in the integration direction
Small components very high very high
Large components with a
measuring step to follow
high medium