00191297-02 - 第386页

11 Station extensions / options User Manual S-23 H M 11.5 PCB data transfer S oftware Version SR.405.xx 05/99 I ssue 384 1 1.5 PCB dat a transfer 1 1.5.1 Functional description The ’Machi ne option s’ menu c ontains a ’P…

100%1 / 422
User Manual S-23 HM 11 Station extensions / options
Software Version SR.405.xx 05/99 Issue 11.4 Feeder position recognition
383
11.4 Feeder position recognition
If the feeder modules are equipped with positioning fiducials, the fiducials can be measured.
If the "Conveyor position detection" function has been selected on the line computer, the function
will also appear in the Machine options. It can then be activated or deactivated at each station.
11
Fig. 11.4 - 1 Feeder position recognition
PLEASE NOTE 11
The "Feeder position recognition" function is always deactivated when the station is switched on. 11
If a track has been entered in the cluster data, the PCB camera on the feeder module will approach
the position of the centering fiducial. Any centering fiducial offset determined during the measure-
ment will then be assigned to this track and added to the pick-up position during the pick-up op-
eration. 11
11 Station extensions / options User Manual S-23 HM
11.5 PCB data transfer Software Version SR.405.xx 05/99 Issue
384
11.5 PCB data transfer
11.5.1 Functional description
The ’Machine options’ menu contains a ’PCB data transfer option. The aim of this function is to
increase the placement system’s performance on the line. To do this, an entire PCB is measured
at the
first
placement station and the associated fiducial, single circuit, ink spot, etc. data is deter-
mined, saved and sent to the next station. At subsequent stations, the data is then determined for
two fiducial positions only. These two fiducial positions are then used to correct the position for the
PCB to be processed at each station. It is thus not necessary to measure the entire PCB again,
together with its single circuits, ink spots etc. 11
11.5.2 Activating the ’PCB data transfer’ option
11
Fig. 11.5 - 1 Machine option: PCB data transfer
User Manual S-23 HM 11 Station extensions / options
Software Version SR.405.xx 05/99 Issue 11.5 PCB data transfer
385
È Click on the ’Machine options’ button in the basic view.
The ’Machine options’ window opens.
È In the ’Options’ box, check the ’PCB data transfer’ option for the station concerned.
È Click on the ’OK’ button. The ’PCB data transfer’ option is now active.
PLEASE NOTE: The ’PCB data transfer option can only be used in conjunction with a PCB bar-
code reader. 11