00191297-02 - 第387页
User Manual S-23 HM 11 S tation extensions / options Software Version S R.405.xx 05/99 Issue 11 .5 PCB data transfer 385 È Cl ick on th e ’Machi ne options ’ button i n the b asic view. The ’Mach ine optio ns’ wi ndow op…

11 Station extensions / options User Manual S-23 HM
11.5 PCB data transfer Software Version SR.405.xx 05/99 Issue
384
11.5 PCB data transfer
11.5.1 Functional description
The ’Machine options’ menu contains a ’PCB data transfer’ option. The aim of this function is to
increase the placement system’s performance on the line. To do this, an entire PCB is measured
at the
first
placement station and the associated fiducial, single circuit, ink spot, etc. data is deter-
mined, saved and sent to the next station. At subsequent stations, the data is then determined for
two fiducial positions only. These two fiducial positions are then used to correct the position for the
PCB to be processed at each station. It is thus not necessary to measure the entire PCB again,
together with its single circuits, ink spots etc. 11
11.5.2 Activating the ’PCB data transfer’ option
11
Fig. 11.5 - 1 Machine option: PCB data transfer

User Manual S-23 HM 11 Station extensions / options
Software Version SR.405.xx 05/99 Issue 11.5 PCB data transfer
385
È Click on the ’Machine options’ button in the basic view.
The ’Machine options’ window opens.
È In the ’Options’ box, check the ’PCB data transfer’ option for the station concerned.
È Click on the ’OK’ button. The ’PCB data transfer’ option is now active.
PLEASE NOTE: The ’PCB data transfer’ option can only be used in conjunction with a PCB bar-
code reader. 11
11 Station extensions / options User Manual S-23 HM
11.5 PCB data transfer Software Version SR.405.xx 05/99 Issue
386