00191297-02 - 第68页
2 Operational Safety User Manual S-23 HM 2.2 Safety equipment Software Vers ion SR.405.xx 05/ 99 Issue 68 (9) Protect ive cover switch (output c onveyor , 003 03617-xx) (10) Prote ctive cover s witch (right, 0032141 7-xx…

User Manual S-23 HM 2 Operational Safety
Software Version SR.405.xx 05/99 Issue 2.2 Safety equipment
67
2.2.3 EMERGENCY STOP mushroom-head push-buttons, protective cover
switches ...
2
Fig. 2.2 - 4 Location of the buttons and protective contactor combinations K1, K2
Key to Fig. 2.2 - 4
(1) Stop button
(2) Start button
(3) EMERGENCY STOP mushroom-head push-button
(4) EMERGENCY STOP mushroom-head push-button
(5) Start button
(6) Stop button
(7) Component counter
(8) Key switch open: position 0 for normal mode
Key switch closed: position I for service purposes

2 Operational Safety User Manual S-23 HM
2.2 Safety equipment Software Version SR.405.xx 05/99 Issue
68
(9) Protective cover switch (output conveyor, 00303617-xx)
(10) Protective cover switch (right, 00321417-xx)
(11) Protective cover switch (input conveyor, 00303614-xx)
(12) Protective cover switch (left, 00321416-xx)
(13) Main power switch
(14) Protective contactor combination K1
(15) Protective contactor combination K2
(16) Compressed air unit
2.2.3.1 Functional description
EMERGENCY STOP mushroom-head push-button 2
When the emergency stop mushroom-head push-button is pressed (item 3 or item 4. in
Fig. 2.2 - 4), the motor voltage to the gantry axes is switched off. The gantry axes are no longer
powered, and thus are not dangerous. 2
PLEASE NOTE
Placement is interrupted and can then either be continued or cancelled once the system is working
correctly again. 2
Protective cover switch 2
If one of the protective covers is opened (see item 9, 10, 11 or 12 in Fig. 2.2 - 4), the gantry axes
will stop immediately. They are no longer powered, and thus are not dangerous. 2
Key switch 2
If the key switch (item 8 in Fig. 2.2 - 4) is closed (position I), the star can still be paced at low speed
while the protective covers are open. The gantry axes are no longer powered, and thus are not
dangerous. 2
PLEASE NOTE
The key switch remains open for normal mode, i.e. in the 0 position. 2
WARNING
The protective covers must only be opened, with the key switch closed (position I), by appropri-
ately qualified and trained personnel. 2

User Manual S-23 HM 2 Operational Safety
Software Version SR.405.xx 05/99 Issue 2.2 Safety equipment
69
2.2.3.2 Status messages and the action required
The following displays may appear in placement mode. If they appear, carry out the action spec-
ified in the third column. 2
2.2.4 Safety circuits
The SIPLACE S-23 HM automatic placement system has two separate safety circuits which are
monitored by protective contactor combinations K1 and K2. Both protective contactor combina-
tions are incorporated into the power supply (see item 14 and 15 in Fig. 2.2 - 4). 2
DANGER
Automatic placement systems from the SIPLACE family are powered with 3x400VAC (3 x 208
VAC U.S.A. version) ± 10%, 50/60Hz mains voltage.
This means that parts of the system carry potentially fatal voltages - even when switched off at the
main switch. Death, serious injury or considerable damage may result if these automatic place-
ment systems are handled incorrectly.
Always follow the applicable accident prevention and DIN regulations (particularly EN 60204,
part 1) and the applicable regulations in your own country.
The guard over the power supply must ONLY be opened by appropriately qualified and trained
personnel. 2
Status Display on screen Action required
EMERGENCY STOP
mushroom-head push-
button pressed
Emergency stop pressed ...
Machine stopped. Release
button
Release the pressed emergency
stop button (item 3 or 4 in Fig. 2.2 -
4)
Press start button Press the green start button (item 2
or 5 in Fig. 2.2 - 4)
Protective cover open Close the cover Close the protective cover (item 9,
10, 11 or 12 in Fig. 2.2 - 4)
Press start button Press the green start button (item 2
or 5 in Fig. 2.2 - 4)
Tab. 2.2 - 1 Screen display when the emergency stop mushroom-head push-button is pressed
or the protective cover is open