Dek印刷机中文培训 - 第18页
17. SCREEN SETUP 钢网类别 D e k P r i n t e r T r a i n i n g 1 8 / 7 0 2 5 J u n e 2 0 0 6

16. SETUP SQUEEGES 设定刮刀
Dek Printer Training 17/70 25 June 2006

17. SCREEN SETUP 钢网类别
Dek Printer Training 18/70 25 June 2006

ADJUSTABLE SCREEN MOUNT (ASM)
ADJUSTMENTS AND SETTINGS
12.6 Technical Reference Manual Chapter Issue 6 Nov 05
ADJUSTMENTS AND SETTINGS
Screen Depth
Adjuster
The screen depth adjuster has two scales as follows:
The rear of stencil to front of image scale, marked on the top of the screen depth
adjuster, can be used for either centre justified or front justified stencils. The
scale has both imperial and metric units as follows:
• Metric - 150mm to 650mm
• Imperial - 6” to 26”
When using this scale the screen depth adjuster is set to the rear of stencil to
front of image value. The figure below shows this measurement for both centre
and front justified stencils
Figure 12-3 Rear of Stencil to Front of Image Measurement
REAR OF STENCIL
TO FRONT OF IMAGE
CENTRE JUSTIFIED IMAGE SIZE
650
622 600 550 500 450 400 350 300 250 200 150
68101214161820222426
508 500 400 300 200
100 0
048121620
Rear of Stencil to Front of Image Scale
Centre Justified Image Size Scale
Front Justified
Rear of Stencil
to
Front of Image
Centre Justified
NOTE
Rear of stencil to front of image is measured from the rear
face of the screen frame to the front edge of the image.
Rear of Stencil
to